1.1. Electronic control system of channel gate   

The electronic control system consists of card reader, main control board, infrared sensor, direction 
indicator board, alarm, transformer, etc. 

Card reader (self-provided): 

after reading the information on the card and judging and processing, 

send the application pass signal (switch signal) to the main control board. 

Master control board:

 the control center of the system, which receives signals from the card reader 

and infrared sensor, makes logical judgment and processing of these signals, and then issues 
execution commands to the direction indicator, motor, counter and alarm. 

Infrared sensor:

 detect the pedestrian position and play the role of safety protection. 

Direction indicator light:

 displays the current status of the channel and guides pedestrians to pass 

through the channel in a safe and orderly manner. 

Alarm:

 when the system detects pedestrians entering the passage illegally, it will send out an alarm 

 

1.2. Operating principle of the system 

a)

 

Turn on the power and the system will enter into working state after 3 seconds. 

b)

 

When the card reader reads the valid card, a pleasant sound will play, indicating to pedestrians 
that the card has been read successfully.   

c)

 

The reader receives the signals from the backend database and after comprehensive processing, 
sends effective control signals to the direction indicator and motor, so that the direction 
indicator sign turns into the green arrow pass sign. At the same time, the turnstile sends the 
setting voice, the main control board controls the motor operation, and the gate is opened to 
allow pedestrians to pass. Otherwise entrance will not be granted with red indicator lights. 

d)

 

After the pedestrian passes through the channel according to the direction indicator, the 
infrared sensor senses the whole process of the pedestrian passing through the channel and 
continuously sends signals to the main control panel until the pedestrian has passed through 
the channel completely. 

e)

 

If entered without permission, the alarm will go off until the passage is cleared again. 

1. Product Structure and Working Principle 

Содержание ID Swing Gate 2400

Страница 1: ...read and follow the installation instructions before operating the equipment and keep the instructions for future reference or use after debugging ID Swing Gate 2400 Date Jan 2024 Version ID Swing Gat...

Страница 2: ...king principle 3 2 Installation instructions 4 5 a Installation notes diagrams 4 b Product dimensions 5 3 Turnstile adjustments connections 6 9 a Gate position adjustment 6 b Circuit board diagram 7 c...

Страница 3: ...an alarm 1 2 Operating principle of the system a Turn on the power and the system will enter into working state after 3 seconds b When the card reader reads the valid card a pleasant sound will play i...

Страница 4: ...recommended 5 If you install multiple devices please make sure to align them properly before drilling holes 6 Connect the power line and control line according to the wiring diagram and connect the s...

Страница 5: ...ID Swing Gate 2400 5 Figure 3 locations inside gate 1 circuit board 2 power supply 3 air break switch...

Страница 6: ...and right positions Users only need to adjust the zero position align the wing gate and wait for the system to exit automatically Adjustment method for door panel position in Flap Gate Mode 1 Press t...

Страница 7: ...00 7 Figure 5 Mainboard description OP L open left OP R open right Fire emergency exit connection Red blue marked buttons setting testing of parameters power connect power 230V counter count up down f...

Страница 8: ...The top light board will move accordingly during adjustments The direction of infrared free passage is displayed with lighted up arrows 2 Gate opening time 1 90 8 Time unit seconds Plus and minus butt...

Страница 9: ...cts the power off gate opening direction based on the current situation The gate opening direction can be referenced to the arrow direction on the top light board 22 Left and right infrared effective...

Страница 10: ...ot there is a faulty battery please contact us for a replacement 4 The arms open normally but fail to close check infrared sensor if it matched well and clean 1 Before installation maintenance or repa...

Страница 11: ...ID Swing Gate 2400 11 iDTRONIC Ludwig Reichling Stra e 4 67059 Ludwigshafen am Rhein Support idtronic zendesk com 6 Support...

Отзывы: