3.2 Parameter Setting
1. Press and hold the INC button (middle button) until the digital tube flashes to enter the parameter
setting.
2. The first and second digits of the digital tube display the menu, and the third and fourth digits
display the value. Press the left button to set the menu and the right buttons to set the value.
3. Press and hold for about 2 seconds, and the digital tube will stop flashing. The menu value is
successfully saved.
Example: As shown in the figure, the current menu is "gate opening mode", and parameter
02 represents "left infrared free passage
"
No. Function
Range
Default
Details
1 Gate opening mode
1~6
1
1: Standard mode. 2: Left infrared free passage. 3: Right infrared free
passage. 4: Left and right infrared free passage. 5: Turnstile normally
open. 6: Turnstile normally closed.
The top light board will move accordingly during adjustments. The
direction of “infrared free passage” is displayed with lighted up
arrows.
2 Gate opening time
1~90
8
Time unit: seconds. Plus and minus button to in- or decrease time
3
Left gate opening
voice prompt
0~9
0
0: Thank you; 1: Please pass; 2: Goodbye; 3: Welcome; 4: Welcome
again; 5: Have a safe journey; 6: Have a pleasant trip; 7: Wear a
safety helmet; 8: Verification successful; 9: Mute;
4
Right gate opening
voice prompt
0~9
3
s.a.
5 Voice volume
1~9
5
Plus and minus button to in- or decrease volume of prompts
6 Main motor speed
1~25
13
When the combination gear ratio of the motor and the movement
mechanism is too low or high, this setting must be adjusted.
7 Slave motor speed
1~25
13
9 Deceleration interval
1~30
10
This parameter is set for a smooth opening/closing of the gate
If the wing gate does not stop in place smoothly and crawls slowly,
consider reducing the parameter;
if the wing gate stops suddenly and shakes significantly, consider