20030516
User’s Manual
25
STAR FINGER007
8. OPERATION
8.1 NORMAL OPERATION
Power ON
When the Power is applied to
FINGER007
, the RED LED is turned on.
Registered Card Reading
When a registered card (or PIN) is read, the Door(Relay 1) will open for 3 seconds(Defaults) with the
Green LED on.
Exit Button
To request for exit from the inside, an Exit Button(or Extra Reader) can be used. The Door(Relay 1) will
open for 3 seconds(Defaults) with the GREEN LED on.
Alarms (unregistered/password/fingerprint/time schedule/door ERROR)
When an unregistered card is read, wrong password is input, wrong fingerprint is input, over the time
schedule, and access wrong door, the access is denied and the alarm(Relay 2) will be activated for 3
seconds(Defaults) with RED LED on.
8.2 DEFAULT SETTING
When you operate the FINGER007 first time or you initialize the
FINGER007
, the controller will setup
all values defaults (factory settings). You can change the settings for desired application.
Please refer to the APPENDIX for the default setting values.