background image

 

 

 FINGER006 SERIES QUICK INSTALLATION GUIDE 

 

1. IMPORTANT SAFETY INSTRUCTION 

When using 

Fingerprint Identification (Proximity / PIN) Reader

, basic safety precautions should   

always be followed to reduce the risk of fire, electrical shock, and injury to persons.   
In addition, the following safety guides should also be followed: 

  1. 

Fully

 read and understand all instructions and follow them completely. 

  2. 

Follow

 all warnings and instructions marked on the product. 

3. 

Do not

 use liquid or aerosol cleaners. Use a damp cloth for cleaning. If necessary, use mild soap. 

   4. 

Do not 

use this product near water. 

  5. 

Only 

operate this product using the type of power source indicated. If you are not sure of the type of power 

supplied to your installation site, consult your dealer of local power company. 

 

  6. 

Never

 insert objects of any kind into the product or through the cabinet slots as they may touch   

voltage points and/or short circuit parts possibly resulting in fire or electric shock.   

Never spill liquid of any kind on the product. 

  7. 

Never

 disassemble this product by yourself; take the unit to a qualified service center   

whenever service or repair is required. Opening or removing the covers may expose you to dangerous voltages 
or other risks. Also, incorrect reassembly can cause electric shock when the unit is subsequently used. 

  8. 

Unplug

 this product from the Direct Current (DC) power source and refer to qualified service   

personnel under these conditions: 

a.

 

When the power supply cord or plug is damaged or frayed. 

b.

 

If liquid has been spilled on the product. 

c.

 

If the product does not operate normally after following the operating instructions in this manual. 
Adjust  only  those  controls  that  are  covered  by  the  operating  instructions  in  this  manual.  Improper 
adjustment of other  controls  that  are  not  covered  by  this  manual  may  damage  the unit and  will  often 
require extensive work by a qualified technician to restore normal operation. 

d.

 

If the product exhibits a distinct change in performance. 

2. WHAT’S INCLUDED 

Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor 
or IDTECK.   

 
 
 
 
 
 
 
 
 
 

 

 

Содержание Star FINGER006

Страница 1: ...Quick Installation Guide Fingerprint Identification Proximity PIN Reader...

Страница 2: ...ck Never spill liquid of any kind on the product 7 Never disassemble this product by yourself take the unit to a qualified service center whenever service or repair is required Opening or removing the...

Страница 3: ...power supply The green LED turns on if access has granted The orange LED turns on if access has failed Finger Print Scanner When users put their finger on the scanner white light will turn on 16 Nume...

Страница 4: ...han 2 seconds Refer to 8 2 System Initialization for more details Communication Display LED 3 4 yellow green LED will twinkle during RS232 RS422 and TCP IP communication If the LAN is connected normal...

Страница 5: ...ed Stripe OK Input OK Input Green Error Input Error Input Green with White Stripe EXTERNAL READER PORT CON5 Wiegand Data0 Wiegand DATA0 Input Pink Wiegand Data1 Wiegand DATA1 Input Cyan OUTPUT CON5 Wi...

Страница 6: ...TX TX Gray RS422 RX RX Blue RS422 RX RX Brown TCP IP Communication CON6 TCP IP Communication Optional 8PIN connector module 3 4 TCP IP Module Option The Finger006 is able to use TCP IP Communication A...

Страница 7: ...ols and readily available communications wires This section provides information about wiring wire runs and other information to make the installation quick and easy 4 1 Check Points before Installati...

Страница 8: ...portion of signal is reflected back into the transmission line The decision whether or not to use termination resistors should be based on the cable length and data rate used by the communication syst...

Страница 9: ...of shield wires to the grounding system in this case there will be a current flow through the shield wire when the voltage level of both ends of shield wire is not equal and this current flow will cre...

Страница 10: ...tep Using 2 screws install wall mount to the wall Insert 5 O Rings to the Wall Mount as indicated then run the cable from the main unit through the center hole and snap in place the main unit to Wall...

Страница 11: ...Board ID Besides the method described above there is one more method for system initialization which is by entering setting menu In this case all setting values will be cleared except Board ID If you...

Страница 12: ...ctor Serial communication connector female is required to connect the FINGER006 to a host computer via RS232 communication Please follow the instructions Connect RS232 TX port of FINGER006 to the pin...

Страница 13: ...other FINGER006 Connect RS422 RX of one FINGER006 to RS422 RX of another FINGER006 Connect RS422 RX of one FINGER006 to RS422 RX of another FINGER006 Second you have to connect one of RS422 port of FI...

Страница 14: ...INGER006 unit Then the LCD will first display Initialize OK 1 Yes 0 No Press 1 key if you want to initialize the system or 0 to cancel the initialization procedure After all the initialization process...

Страница 15: ...the current date and time To adjust the time date setting press ENT then enter 15 Digits in a YYYYMMDDhhmmssW format and then enter ENT again to confirm NOTE For the days of the week W 1 Sun 2 Mon 3 T...

Страница 16: ...from OK output wire for 500ms Default Registered Card Reading When a registered card or PIN is read the door will open for 3 seconds Defaults with the GREEN LED on Alarms Unregistered Password Finger...

Страница 17: ...FINGER006 SERIES QUICK INSTALLATION GUIDE 17 9 Template...

Отзывы: