background image

 

 

 FINGER006 SERIES QUICK INSTALLATION GUIDE 

 

15 

7.2 How to Enter the Setup Menu

 

For a setup or FINGER006 setting adjustment, you have to enter the SETUP MENU, first. To do so, press the <0> key 
8 times for Master ID (Default “00000000”) and the user can get into the SETUP MENU. There are 4 main SETUP 

MENUs and you first get into [SETUP MENU F1]. You can move to other SETUP MENUs by pressing <F1> key for 
[SETUP MENU F1], <F2> key for [SETUP MENU F2], <F3> key for [SETUP MENU F3], and <F4> key for [SETUP 
MENU F4]. There are several SUB MENUs for each main SETUP MENU and you can scroll up and down the SUB 
MENU by pressing <4> and <6> key in the main SETUP MENU. You can press the <ESC> key to exit the SETUP 

MENU and return to the normal operation. You can also change the Master ID in the [SETUP MENU F1]. The Master 
ID for FINGER006SR is a 10-digit number (Default “0000000000”).

 

7.3 Time / Date Setting 

After you enter the Setup Mode, you will see the following screen with the current date and time. To adjust the time / 

date setting, press 

<ENT>

, then enter 15 Digits in a YYYYMMDDhhmmssW format, and then enter 

<ENT> 

again to 

confirm. 

 
 

 
 
 

NOTE:

 For the days of the week (W), 1 : Sun, 2 : Mon, 3 : Tue, 4 : Wed, 5 : Thu, 6 : Fri, 7 : Sat. 

e.g.

 To input August 24, 2009, 13:30:15, Monday, enter 200908241330152. 

 

7.4 Maximum Number of Cardholder IDs 

By  default,  the 

FINGER006

  is  set  to  store  up  to  10,000  cardholders  and  50,000  events

 

and  User  can’t  change 

Maximum Number of Cardholder IDs because FINGER006 doesn’t have the controller inside. 

7.5 Registering Cardholder IDs 

To add new cardholder IDs to the 

FINGER006

, enter the Setup Mode (See 7.2 How to Enter Setup Mode), press 

<F3>

Once the 1.ID registration item appears on the LCD, press 

<ENT> 

to begin the ID registration process. 

For detailed information on the ID registration process, please refer to “12.3.1 registration” of the main manual.   

 
 
NOTE: 

How to place your finger onto the scanner: 

When you register or verify your fingerprint, please place your finger onto the scanner correctly as illustrated below. 

 

 
 

 
 
 
 

Figure: How to Put Your Finger on the Scanner 

 

 

1. TIME SETTING 

MM/DD hh:mm:ss 

YYYYMMDDhhmmssW 

 

<ENT> 

Содержание Star FINGER006

Страница 1: ...Quick Installation Guide Fingerprint Identification Proximity PIN Reader...

Страница 2: ...ck Never spill liquid of any kind on the product 7 Never disassemble this product by yourself take the unit to a qualified service center whenever service or repair is required Opening or removing the...

Страница 3: ...power supply The green LED turns on if access has granted The orange LED turns on if access has failed Finger Print Scanner When users put their finger on the scanner white light will turn on 16 Nume...

Страница 4: ...han 2 seconds Refer to 8 2 System Initialization for more details Communication Display LED 3 4 yellow green LED will twinkle during RS232 RS422 and TCP IP communication If the LAN is connected normal...

Страница 5: ...ed Stripe OK Input OK Input Green Error Input Error Input Green with White Stripe EXTERNAL READER PORT CON5 Wiegand Data0 Wiegand DATA0 Input Pink Wiegand Data1 Wiegand DATA1 Input Cyan OUTPUT CON5 Wi...

Страница 6: ...TX TX Gray RS422 RX RX Blue RS422 RX RX Brown TCP IP Communication CON6 TCP IP Communication Optional 8PIN connector module 3 4 TCP IP Module Option The Finger006 is able to use TCP IP Communication A...

Страница 7: ...ols and readily available communications wires This section provides information about wiring wire runs and other information to make the installation quick and easy 4 1 Check Points before Installati...

Страница 8: ...portion of signal is reflected back into the transmission line The decision whether or not to use termination resistors should be based on the cable length and data rate used by the communication syst...

Страница 9: ...of shield wires to the grounding system in this case there will be a current flow through the shield wire when the voltage level of both ends of shield wire is not equal and this current flow will cre...

Страница 10: ...tep Using 2 screws install wall mount to the wall Insert 5 O Rings to the Wall Mount as indicated then run the cable from the main unit through the center hole and snap in place the main unit to Wall...

Страница 11: ...Board ID Besides the method described above there is one more method for system initialization which is by entering setting menu In this case all setting values will be cleared except Board ID If you...

Страница 12: ...ctor Serial communication connector female is required to connect the FINGER006 to a host computer via RS232 communication Please follow the instructions Connect RS232 TX port of FINGER006 to the pin...

Страница 13: ...other FINGER006 Connect RS422 RX of one FINGER006 to RS422 RX of another FINGER006 Connect RS422 RX of one FINGER006 to RS422 RX of another FINGER006 Second you have to connect one of RS422 port of FI...

Страница 14: ...INGER006 unit Then the LCD will first display Initialize OK 1 Yes 0 No Press 1 key if you want to initialize the system or 0 to cancel the initialization procedure After all the initialization process...

Страница 15: ...the current date and time To adjust the time date setting press ENT then enter 15 Digits in a YYYYMMDDhhmmssW format and then enter ENT again to confirm NOTE For the days of the week W 1 Sun 2 Mon 3 T...

Страница 16: ...from OK output wire for 500ms Default Registered Card Reading When a registered card or PIN is read the door will open for 3 seconds Defaults with the GREEN LED on Alarms Unregistered Password Finger...

Страница 17: ...FINGER006 SERIES QUICK INSTALLATION GUIDE 17 9 Template...

Отзывы: