11
Quick Installation Guide
6. RECOMMENDED CABLE TYPE AND PERMISSIBLE LENGTH
* : For readers, thicker wires are needed if you connect the reader with high current consumption.
7. REVERSE DIODE CONNECTION
If you connect the output device with coil (Door Locks or Alarm device) to the output relays, there will
be a high surge voltage created while the inductor is turning on and off. If you do not connect a reverse
diode, the surge voltage will transfer and damage the electronic circuit of the controller.
It is strongly recommended to add a reverse diode between the inductor coils to absorb this surge voltage.
Figure: Reverse Diode Connection
Reference
Description
Cable Specification
Maximum
Distance
1
100R series Power (DC12V)
DC Power-> 100R series
Belden #9409,18 AWG
2 conductor, unshielded
30m
* 2
Reader(Power and Data)
External Reader
Belden #9512,22 AWG
4 conductor, shielded
150m
Belden #9514,22 AWG
8 conductor, shielded
3
Door Contact
Exit Button
Sensor Input
Input-> 100R series
Belden #9512,22 AWG
4 conductor, shielded
300m
Belden #9514,22 AWG
8 conductor, shielded
4
Door Lock
Alarm Device
Lock(Alarm)-> 100R Series
Belden #9409,18AWG
2 conductor, unshielded
300m