15
Quick Installation Guide
8.7 Auto-Dialer Connection (Separate purchase required)
The Auto-dialer function of this unit has not been evaluated by UL.
●
Connect the input wire of Auto-Dialer to TTL output, Orange with White stripe wire.
●
Connect (+) wire of Auto-Dialer to DC +12V (be sure that the existing power supply has enough
capacity to support this accessory or upgrade to a sufficient one.)
●
Connect (-) wire of Auto-Dialer to Power GND (-) wire.
●
Connect Telephone Line plug (RJ-14) to Auto-Dialer.
(If an active High Auto-Dialer is used, then see section 12-59 to change the TTL output
level from the defaulted setting.)
8.8 Wiegand Input Connection from Another Compatible Wiegand Reader
(Separate purchase required)
●
Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has enough capacity
to support this accessory or upgrade to a sufficient one.)
●
Connect (-) wire of Reader to Power GND (-) wire.
●
Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
●
Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
8.9 Chime Bell Connection (Separate purchase required)
●
Connect (+) wire of Chime Bell unit to Bell Output, Brown with White stripe wire of Main
Unit.
●
Connect(-) wire of Chime Bell unit to Power GND(-) wire.