IDS LCD Digital Keypad Скачать руководство пользователя страница 23

23

 

IDS LCD Keypad User Manual   700-292-01C   Issued March 2009 

 

 

8.3.10                          Option 9 - Delete User Code (Code known)                               

 

Hold [*] + [Master Code] + [*] + [9] + [*] + [User Code to be deleted] + [*] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of (8.2). 

2.

 

IDS 816 Panel

 

 

When prompted for the 'Menu Option' press the 

[9]

 key followed by the 

[

*

key to select 

programmable option 9.  

 

IDS 1632 & IDS 1224 Panels 

 

Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To select menu option 9 - 

'Default Code', press the 

[9]

 key or alternatively use the 

[PANIC]

 or 

[MED] 

keys to scroll 

through the list of programmable options until you reach Menu Option 9. Press the 

[

*

]

 to confirm 

your selection. 

3.

 

The ARM LED will flash. 

4.

 

When prompted for the 'User Code' enter the 

[USER CODE]

 to be deleted followed by the

 

[

*

]

 

key. 'Deleting' the code in slot one will reprogram it to 1234. 

5.

 

Further codes may be deleted by repeating Step 4 above. 

6.

 

After deleting the final code, press the

 

[#]

 key to exit User Program Mode. 

 

8.3.11                       Option 10 - Delete a User Code ("Slot" known)                                  

 

Hold [*] + [Master Code] + [*] + [1] + [0] + [*] + [User Slot] + [*] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of (8.2). 

2.

 

IDS 816 Panel 

 

When prompted for the 'Menu Option' press the 

[1]

 key followed by the 

[0]

 key to select 

programmable option 10. 

 

IDS 1632 & IDS 1224 Panels

 

Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To select menu option 10 - 

'Default Slot', press the 

[1]

 key followed by the 

[0]

 or alternatively use the 

[PANIC]

 or 

[MED]

 

keys to scroll through the list of programmable options until you reach Menu Option 10. Press the 

[

*

]

 to confirm your selection. 

3.

 

The ARM indicator flashes and the LCD prompt reads 'Enter User Slot'. 

4.

 

When prompted for the 'User Slot' enter the 

[SLOT NUMBER]

 for the User Code you wish to 

delete followed by the 

[

*

]

 key. 

5.

 

Further User Codes may be deleted by repeating Step 4. 

6.

 

After deleting the final code, press the 

[#]

 key to exit User Program Mode. 

 

8.3.12                                  Option 11 - Viewing a User Name                                        

 

Hold [*] + [Master Code] + [*] + [1] + [1] + [*] + [User Slot] + [*] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of (8.2). 

2.

 

IDS 816 Panel 

 

When prompted for the 'Menu Option' press the 

[1]

 key followed by the 

[1]

 key to select 

programmable option 11.  

IDS 1632 & IDS 1224 Panels

 

Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To select menu option 11 - 

'Slot Name', press the 

[1]

 key followed by the 

[1]

 or alternatively use the 

[PANIC]

 or

 

[MED] 

keys 

Содержание LCD Digital Keypad

Страница 1: ......

Страница 2: ...2 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Страница 3: ...3 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Страница 4: ...4 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Страница 5: ...Fire Alarms 12 5 2 Panic Alarms 12 5 3 Medical Alarms 13 5 4 Duress Alarms 13 6 Alarm Memory 13 7 Zone Options 13 7 1 Changing a Zone Name 13 8 User Codes 14 8 1 Adding Deleting and Editing User Code...

Страница 6: ...0 Delete a User Code Slot Known 23 8 3 12 Option 11 Viewing a User Code 23 8 3 13 Option 12 Add User Slot 24 9 Stay Zones 24 9 1 How to Select a Stay Profile 24 9 2 How to Program Stay Zones 24 9 3 Ho...

Страница 7: ...0 292 01C Issued March 2009 Tables Table 1 Alarm Panel Zones 13 Table 2 Alarm Panel Features 14 Table 3 User Programming Options 15 Table 4 User Code Properties 19 Table 5 Trouble Conditions 27 Table...

Страница 8: ...ed by motion detectors If necessary bypass any required zones and close the front door 2 Press the key 3 Enter a valid USER CODE If an incorrect code is entered the keypad buzzer will beep three times...

Страница 9: ...ing television when all interior zones would be bypassed See 9 1 How to Select a Stay Profile 2 2 1 How to Stay Arm USER CODE Do not leave premises 1 Select the required STAY PROFILE See Section 8 1 2...

Страница 10: ...e the PANIC and MED keys to scroll through zones which have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a designated exit route 2 At the en...

Страница 11: ...e system will disarm and the remote indicator if installed will turn off If the siren toot on disarm option is enabled the siren will provide a double toot when the panel is disarmed 4 Bypassing Zones...

Страница 12: ...on will be activated The Display reads Alarm alongside the relevant partition The FIRE ALARM CONDITION may also be triggered by a smoke detector connected to an appropriately programmed zone The siren...

Страница 13: ...can be easily remembered by all family or staff members 6 Alarm Memory The Alarm Memory displays any zones which were tampered violated or bypassed during the last arm cycle A flashing ARM indicator...

Страница 14: ...i e to display a 2 press the relevant key four times If you wish to use a different letter on the same key press the key the required number of times to display the relevant letter pause for one secon...

Страница 15: ...d user code to a designated partition s This is a bitmapped menu x x x Option 6 Assign User Code to Doors bitmapped x Option 7 Assign a User Code to a Schedule x Option 8 Allows a remote to be assigne...

Страница 16: ...r Code Hold Master Code 0 New Code 1 Enter the User Program Mode as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 0 key followed by the key to select programmable op...

Страница 17: ...Example You wish to change USER 1 to read Brad 1 To type in a B press the 2 key twice B is the second letter displayed on the key 2 Text is defaulted to Upper case Press the MODE key for lower case Up...

Страница 18: ...Code Property Number 1 Enter the User Program Mode as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 4 key followed by the key to select programmable option 4 IDS 16...

Страница 19: ...ol panel disarms normally however a DURESS REPORTING CODE is transmitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder It is advisable t...

Страница 20: ...l disarm all of the assigned partitions In a case where some partitions are disarmed and others armed entering this group code at the keypad of the armed partition will disarm the armed partitions onl...

Страница 21: ...will be a Y next to Option 1 and the user can thus arm and disarm partition 1 If the user is assigned to partition 4 there will be a Y next to Option 4 It is possible to program codes to arm disarm an...

Страница 22: ...If a user is assigned to Schedule 0 the user may arm disarm the premises at any given time Users assigned to Schedule 1 are allowed to arm disarm the area only during the specified programmed schedule...

Страница 23: ...de as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 1 key followed by the 0 key to select programmable option 10 IDS 1632 IDS 1224 Panels Menu option 0 Add User is d...

Страница 24: ...hose zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms which are protected by Passive Infra Red PIR detectors or windows which m...

Страница 25: ...ively use the PANIC and MED keys to scroll through zones 4 A N next to the zone number indicates that the zone is not selected as a stay zone 5 Repeat step 3 until all the required stay zones have bee...

Страница 26: ...4 A N next to the zone number indicates that the zone has not been selected as a buzz zone 5 Repeat step 3 until all the required buzz zones have been cancelled 6 Press the key to exit the buzz zone...

Страница 27: ...is also possible to enable a trouble beep If the trouble beep has been enabled the keypad buzzer will sound to alert the user that a trouble condition has occurred Press the key to silence the buzzer...

Страница 28: ...e ring Dial in again within 1 minute the panel will pick up immediately and transmit handshake tones consisting of a high pitch tone for two seconds followed by a lower pitch tone for one second Withi...

Страница 29: ...tes that the zone was successfully un bypassed Three Error Beeps indicates that a key entry error has occurred Check Zone Bypass Status 2 3 ZONE A Single Beep indicates that the zone is bypassed A Dou...

Страница 30: ...to control switching functions via its outputs these can be controlled via the keypad e g turning lights on and off Hold down the MODE key and press 3 Any outputs that are currently set ON will be dis...

Страница 31: ...er Code Press Tx Button Delete a User Code by Code Master Code 9 User Code Delete a User Code by Slot Number Master Code 10 Slot Number Change Partitions Mode 1 Partition Number Select a Stay Profile...

Страница 32: ...32 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Отзывы: