background image

Owner’s Manual 

700-624-01C 

Glossary 

Alarm Memory   

This is the history of the most recent violations that occurred the last time the system was 
armed. (See pg. 16) 

Arm

 

To set the system into the ARMED mode. In this mode, violating a zone will activate an 
alarm condition. If the system is programmed accordingly, it will cause a reporting code 
to be sent to the monitoring company

(See pg. 10)

 

Bypass

 

     

To deactivate a zone. When the panel is ARMED, violation of a bypassed zone will be 
ignored. (See pg. 14) 

Disarm       

To deactivate the system. Fire, medical and panic functions remain active while the 
system is disarmed. (See pg. 14) 

Entry/Exit

 

Zone

  

A zone with a programmable time delay, which allows the user to exit the premises after 
arming the system and time to get to the keypad after entering the armed premises. This 
zone is generally the last exit point of the building and the first entry point i.e. the front 
door of a home. 

Follower Zone     

A zone that may be temporarily violated during the exit delay period or after violation of 
an Entry/Exit zone. This allows the user access to disarm the system. A Follower zone will 
behave as per an Instant zone if violated prior to the violation of an Entry/Exit zone. 

Instant

 

Zone

    

    

When the system is armed, violation of an Instant zone will immediately cause an alarm 
condition to be registered. 

Stay Arm    

Arming that allows for certain preprogramed, STAY zones to be violated while the system 
is armed

(See pg. 11)

 

Stay Arm and Go 

Arming that allows the user to STAY ARM and leave the premises. (See pg. 12) 

Stay Zone   

Zones which are bypassed automatically when the system is STAY ARMED. (See pg. 11) 

Zone 

A specific area of your premises guarded by sensors which detect violations of that area. 

Содержание IDS806

Страница 1: ...IDS806 Owner s Manual South Africa s leading manufacturer and distributor of electronic security products...

Страница 2: ...Owner s Manual 700 624 01C 2 For Service Central Station Information Account Telephone Installer Information Account Telephone This alarm is to be installed and maintained by an IDS trained installer...

Страница 3: ...System Information 9 Arming the System 10 Disarming the System 14 Emergency Situations 15 System Memory 16 System Configuration 17 Remote Transmitter 21 Date and Time 23 Troubleshooting 24 Problems w...

Страница 4: ...n away mode Armed icon will be on when the system is armed in stay or away mode Ready Icon will be on when the system is in an arm able state Star Key is used to bypass zones and enter the master user...

Страница 5: ...e keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower Zone A zone that may be temporaril...

Страница 6: ...otes 1 This alarm is to be installed and maintained by an IDS trained installer 2 Read the entire manual carefully and keep it in an accessible place 3 Your security system should be installed and ser...

Страница 7: ...Information Icons Description System Disarmed System Away Armed Alarm Condition Check Alarm Memory zone details BEFORE re arming System Stay Armed Stay Alarm Condition Mains Power is Present Trouble C...

Страница 8: ...ty the keypad will automatically enter into a power save mode by turning off all the indicators The keypad wakes up or comes on when any key is pressed or any zones are violated The power save feature...

Страница 9: ...or Follower Zones Violated Stay Arm Stay Arm and Go Forced Arming Siren Sound on Arm Disarm single toot arm double2 toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Monitoring Arm...

Страница 10: ...ion detectors 2 If necessary close the front door 3 Press the key to cancel any unintended key entries 4 Enter a valid 4 digit USER CODE If you make a mistake press the key and re enter the code 5 The...

Страница 11: ...once the family retires to their bedrooms All bedrooms would therefore be STAY zones bypassed while unused zones i e a lounge and TV room together with perimeter zones would be normal alarm zones NOT...

Страница 12: ...the system will arm in AWAY mode 8 Any STAY zones shown by a steadily lit indicator will be automatically bypassed 9 Ensure that you enter only those zones that are bypassed Quick Stay Arming Hold dow...

Страница 13: ...rm and disarm or a LED indicator to verify function enabled Auto Arming Your system can be programmed to automatically arm itself daily at a preprogramed time Ask your installer to program this functi...

Страница 14: ...ress the number corresponding to the currently bypassed zone 3 The zone indicator will turn off the zone is now active Disarming the System Disarming with a User Code USER CODE To disarm the system en...

Страница 15: ...FIRE ALARM condition will be activated The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an appropriately programmed zone The siren will sound 1 second on 1 second off a...

Страница 16: ...the system was armed If the ARMED indicator is flashing before you disarm the system a violation has occurred To view which zone was violated Hold down the key until the beep 1 Disarm the panel with...

Страница 17: ...Code Code 15 Duress Code Entering New and Changing Existing User Codes MASTER USER CODE CODE NUMBER NEW CODE 1 Hold down the key until the keypad buzzer sounds 2 The ARMED and READY indicators will f...

Страница 18: ...ystem Stay Zones Stay zones are those zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms or other areas which require access must...

Страница 19: ...buzz zones will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will...

Страница 20: ...exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone To Program the Chime Zones ZONE NUMBER 1 Hold down the 2 key until the keypad buzzer s...

Страница 21: ...ed to transmit IDS Xwave protocol and buttons 2 4 IDS keeloq protocol see Figure 2 Remote Transmitter Button Defaults Each button can be changed individually To change a button from one protocol to an...

Страница 22: ...the remote is learnt If the users arm disarm code is known MASTER CODE 20 USER CODE PRESS REMOTE BUTTON 1 Press and hold the for 3 seconds and the keypad will confirm with a beep 2 Enter the Master C...

Страница 23: ...Action 0 No Action 8 PGM 4 on for 2 seconds 1 Arm 9 PGM 5 on for 2 seconds 2 Stay Arm 10 PGM1 Toggle 3 Stay Go 11 PGM2 Toggle 4 Panic 12 PGM3 Toggle 5 PGM 1 on for 2 seconds 13 PGM4 Toggle 6 PGM 2 on...

Страница 24: ...ch lit zone LED The system will automatically exit the TROUBLE mode after ten seconds To clear the trouble condition press after viewing the trouble To simply cancel the beeping without viewing the tr...

Страница 25: ...efore you exit The exit delay may be too short ask your installer to adjust the exit delay OR You have not left via a Follower and Entry Exit zone or have strayed into an Instant zone Either avoid the...

Страница 26: ...for 1 second Fire Hold down for 1 second Medical Emergency Hold down for 1 second Alarm Memory Hold down for 1 second Change Stay Profile Stay Profile or Stay Profile Bypass a zone Zone to Zone Progr...

Страница 27: ...ng User Codes 17 Fire Alarm 15 For Service 2 Forced Arming 13 Glossary 5 Introduction to the IDS806 6 Learning a Remote Transmitter to a User Code 22 Maid s Code 18 Medical Alarm 16 Notes 6 Panic Alar...

Страница 28: ...Stay Zones 18 To Program the Chime Zones 20 To Stay Arm 12 To Un bypass a Zone 14 Trouble Conditions 24 Troubleshooting 24 Understanding the Keypad Indicators 7 User Codes 9 17 Viewing Trouble Condit...

Страница 29: ...Owner s Manual 700 624 01C 29...

Страница 30: ...Owner s Manual 700 624 01C 30...

Страница 31: ...Owner s Manual 700 624 01C 31...

Страница 32: ...Manual 700 624 01C 32 For electronic swop out it is not necessary to return the enclosure The 806 Products are a product of IDS Inhep Digital Security and is manufactured by Inhep Electronics Holdings...

Отзывы: