IDS 816 700-283-02I Issued September 2009
20
Table 4 : Programmable Zone Types
Value
Zone Type
0
DISABLED
A Zone violation of a disabled zone is ignored by the control panel and will not be indicated on
the keypad.
1
PRIMARY ENTRY / EXIT ZONE
Violations of an Entry/Exit zone are ignored during the exit delay period of the arming
procedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If valid User
Code is not entered before the entry delay period expires, an alarm condition will be registered.
Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm.
This zone may also function as an Entry/Exit zone that is COMMON to two partitions. In such a
case, should a user violate this zone and then disarm his partition, the OTHER partition will re-
arm after the entry delay.
8
SECONDARY ENTRY / EXIT ZONE
The secondary entry delay will be activated if this zone is violated when the panel is armed.
2
FOLLOWER ZONE
A violation of a Follower zone is ignored during the entry/exit delay period (this allows the user
to enter/exit via the Follower zone). A Follower zone will behave as an instant zone if the panel is
armed and an Entry/Exit zone is not violated prior to violation of the follower zone.
3
PANIC / PRIORITY ZONE
Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the
control panel to register a panic condition.
This zone type CANNOT be bypassed.
4
INSTANT ZONE
When the panel is armed the violation of an instant zone will cause the control panel to register
an alarm condition.
5
ARM/DISARM ZONE
The violation of an Arm/Disarm zone will cause the panel to toggle between (away) armed and
disarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit to
this zone.
9
RESERVED
10
FIRE ZONE
Violation of a Fire zone will cause the siren to sound regardless of whether the panel is armed or
not. The siren will sound intermittently (one second on, one second off) For correct operation a
programmable output programmed as a fire detector power output must be used to control
power to the fire detector.
There is a 10 second violation when unarmed and instant when armed.
11
TAMPER ZONE
Violation of this zone will be reported to the base station regardless of whether the panel is
armed or disarmed. If the panel is armed, the siren will be activated.
12
24 HOUR ALARM ZONE
This works the same as a panic zone – with the exception that it can be bypassed.
13
WARNING ZONE
When the panel is armed, violation of a warning zone will cause the siren to beep. The violation
is logged in the event log but it is not reported to the base station. Warning zones may be
included and will be counted when used as part of the cross-zone matrix.
14
PUSH TO ARM ZONE
Violation of a push to arm zone during the exit delay will immediately arm the panel.
15
OUTDOOR INSTANT ZONE
When the panel is armed violation of an outdoor instant zone will cause the panel to register an
alarm condition.
Содержание 816
Страница 1: ......
Страница 2: ...IDS 816 700 283 02I Issued September 2009 2...
Страница 6: ...IDS 816 700 283 02I Issued September 2009 6...
Страница 7: ...IDS 816 700 283 02I Issued September 2009 7...
Страница 61: ...IDS816 User Manual 700 283 01H Issued January 2009...
Страница 62: ...IDS816 User Manual 700 283 01H Issued January 2009...
Страница 64: ...IDS816 User Manual 700 283 01H Issued January 2009...