IDS 816 700-283-02I Issued September 2009
28
LOCATION 44
Keypad Lockout Time (Default = 30 seconds)
The value programmed into this location determines the keypad lockout period. The valid range is 0 - 255
seconds.
NOTE:
Keypad lockout is enabled by partition. See Partition Options Page 44, sub-location 5.
LOCATION 45
Keypad Sleep Delay (Default = 5 seconds)
The values stored in this location work in the same way as siren delay (table on page 27). The default
value is 11, which equates to 5 minutes.
NOTE:
This function is set individually per keypad (locations 400 to 407). After this time period, if there is no
keypad activity (on this keypad) the backlighting and all other status and alarm indicators will turn off. The
power LED and if appropriate, the arm LED will remain on.
LOCATION 46
User and Installer Code Number of Digits
This location determines whether 4 or 6 digit user / installer codes are applicable. Only a value of four or
six may be programmed into this location. By default, all codes are four digits in length.
The value programmed into this location has no effect on the download code, which is always 4 digits in
length.
Code
Old Four-digit Code New Six-digit Code
All Previously
Programmed Codes
XXXX
XXXX00
Installer Code
9999
999999
Master User Code 1
1234
123456
8. System Reporting Codes (4 x 2 and Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code
a double zero (00) must be entered into the corresponding location. Note that if one of the above-
mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be
reported. The exception to this rule is when using domestic reporting where only the first digit is used.
LOCATION 47
AC Failure Reporting Code
The control panel will transmit this code in the event of an AC failure but only after the AC failure delay
time has elapsed (location 39).
LOCATION 48
AC Restoral Code
The control panel will transmit this code once the AC restore delay time has elapsed. (location 39). It will
however only be reported if an AC failure was registered as per location 47.
Содержание 816
Страница 1: ......
Страница 2: ...IDS 816 700 283 02I Issued September 2009 2...
Страница 6: ...IDS 816 700 283 02I Issued September 2009 6...
Страница 7: ...IDS 816 700 283 02I Issued September 2009 7...
Страница 61: ...IDS816 User Manual 700 283 01H Issued January 2009...
Страница 62: ...IDS816 User Manual 700 283 01H Issued January 2009...
Страница 64: ...IDS816 User Manual 700 283 01H Issued January 2009...