Federal Communications Commission Statement

This device complies with Part 15 of the FCC. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference

to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, 

the user isencouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help.

DECLARATIONS AND SAFETY STATEMENTS

IC Regulations

This Class B digital apparatus complies with Canadian ICES-003 .

Cet appareil num

é

rique de la classe B est conforme 

à

 la norme NMB-003 du Canada.

This device complies with Industry Canada licence-exempt RSS-210 standard. Operation is subject to the following 

two conditions: 

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that 

may cause undesired operation of the device. 

INFORMATION PAGE

Programming code

Name

User code

Name

User code

52

1. Do not share the programming code with anyone else.

2.Keep a written copy of all vaild user codes in a safe place.

( You may use the table below to record your information)

3. The memory capacity for user codes is 10 sets.

4. It is STRONGLY recommended changing all codes if any security information in the table is lost.

SECURITY INSTRUCTION

Содержание EL730SLR

Страница 1: ...ble any internal components of this lockset as this WILL void the limited warranty 2 Do not drop or hit strike the lockset as excessive shock may result in permanent damage 3 Do not use sharp objects...

Страница 2: ...s que vous souhaitez conserver telles que le code de programmation et les codes d utilisateur Veuillez utiliser la derniere page de ce manuel comme reference 5 Veuillez changer le code de programmatio...

Страница 3: ...by entering a valid code Thumbturn 2 To program the lockset 2 Red light Code entered is invalid Under setup mode 3 Yellow light Low battery warning All batteries should be replaced if yellow light fla...

Страница 4: ...on when holding the Lock Button for over 3 seconds 1 2 3 4 5 6 7 8 9 0 C Inductive Zone 04 LED Indicator Lock Button Unlock Button Inductive Zone RFID Card Remote Control PROGRAMMING CODE AND USER CO...

Страница 5: ...rative Cover K Adjustable Latch Square or radius faceplate or drive in L 6 8 19mm Wood Screw 4 M Strike Plate N Reinforced Strike Plate O Dust Box B Cable C Tailpiece D Mounting Plate COMPONENTS E 1 1...

Страница 6: ...k centerline on door for for deadbolt about 3 to 6 75 mm to 150 mm above the existing knob or lever b Stand so door swings towards you Align template on centerline and fold template as shown Centerlin...

Страница 7: ...he door face from both sides to avoid wood splitting 11 DRILL HOLES b Drill a 1 25 mm hole on the door edge for the latch c Use the faceplate as a template for mortise and pilot holes Chisel 1 8 3 mm...

Страница 8: ...ike dimension Note The dust box and reinforced strike plate are optional It is recommended to install both of them for maximum security 13 LATCH BACKSET ADJUSTMENT Latch backset adjustment only needs...

Страница 9: ...your door is not a drive in latch type please skip this step 15 INSTALLATION INSTRUCTIONS INSTALL LATCH IN MORTISED AREA OR INSTALL DRIVE IN LATCH If the door is designed for a standard type latch pl...

Страница 10: ...nder the latch Thread the tailpiece through the latch in horizontal position 5 16 Drill a 5 16 8mm hole on the door when the screw post is installed INSTALLATION INSTRUCTIONS 6 17 The bulged part of m...

Страница 11: ...the door Fasten the mounting plate with 2 1 8 54mm screws 2 and 1 1 4 32mm screw 1 Note Screw E is an optional screw We recommend using screw E for the stability of the lockset 8 REMOVE THE DECORATIV...

Страница 12: ...IONS 9 20 Connect the cable into the connector port firmly The metal connector side should face outside Note The red portion of the cable is aligned with the red portion of the connector port Cable Co...

Страница 13: ...UTOMATIC BOLT DIRECTION DETERMINATION 1 Press and hold SET button for over 2 seconds The Red LED will light up and beep twice You are now under setup mode 2 Enter 123456 or current programming code an...

Страница 14: ...e operating the lockset 1 2 3 4 5 6 7 8 9 0 C 25 Steps are as follows 1 Press and hold SET button for over 2 seconds The Red LED will light up and beep twice You are now under setup mode 2 Enter 12345...

Страница 15: ...ter accessing setup mode AA AA AA AA SET DEL 1 2 3 4 5 6 7 8 9 0 C 27 SETUP MODE HOW TO ADD A PROXIMITY CARD only available for Proximity Card Electronic Deadbolt Steps are as follows 1 Press and hold...

Страница 16: ...ss button Press button User codes can be stored to 5 sets Remote controls can be stored to 5 sets Touch the inductive zone Proximity cards can be stored to 5 sets 30 Note 1 The lockset will go back to...

Страница 17: ...back to the standby status if no button is pressed in 10 seconds after accessing setup mode 32 HOW TO DELETE AN INDIVIDUAL EXISTING PROXIMITY CARD only available for Proximity Card Electronic Deadbolt...

Страница 18: ...e keypad and repeat above step prior to the indicator light timing out 10 seconds after the last press of a keypad button Note 1 The lockset will go back to the standby status if no button is pressed...

Страница 19: ...ls and re add current cards remote controls excluding the lost one C AA AA AA AA SET DEL 1 2 3 4 5 6 7 8 9 0 C 36 HOW TO DIABLE ALL EXISTING CODES CARDS REMOTE CONTROLS VACATION MODE Steps are as foll...

Страница 20: ...ccessing setup mode 38 AA AA AA AA SET DEL 1 2 3 4 5 6 7 8 9 0 C SETUP MODE HOW TO ENABLE AUTO LOCK MODE Steps are as follows 1 Press and hold SET button for over 2 seconds The Red LED will light up a...

Страница 21: ...C 40 SETUP MODE HOW TO ENABLE DOUBLE AUTHORIZATION MODE only available for Proximity Card Electronic Deadbolt Remote Control Electronic Deadbolt Steps are as follows 1 Press and hold SET button for ov...

Страница 22: ...lling the lock on the door All existing user codes cards remote controls will be deleted Lock will be restored to the pre set programming code of 1 2 3 4 5 6 Please change the programming code and add...

Страница 23: ...ock button on the remote control to unlock the lockset 2 When the double authorization mode is turned on both user code and card or both user code and remote control must be authenticated to unlock th...

Страница 24: ...ckset did not operate correctly after installation QUESTIONS ANSWERS Feel a bump while turning of the motor 1 Please rotate the thumbturn back and forth a few times 1 Check center of strike hole for a...

Страница 25: ...ou have entered the correct programming code 3 button should be held over 3 seconds I cannot add a new user code 1 Make sure all code inputting processes should be completed within 10 seconds 2 Make s...

Страница 26: ...iate LED backlight The card or the remote control is lost 1 For your safety please delete all cards remote controls and re add current cards remote controls excluding the lost one C 50 TROUBLESHOOTING...

Страница 27: ...reception which can be determined by turning the equipment off and on the user isencouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receivi...

Отзывы: