VAC-5000HD User Guide
47
11 Fuse
The VAC is equipped with a glass tube-type fuse (5 × 20 mm/0.2 x 0.79”), which prevents overcurrent from
flowing into the VAC when a circuit or circuit part is broken.
If the VAC cannot be turned on, first check if the fuse placed in the AC inlet is blown or not. If it is blown,
replace the blown fuse with the spare fuse by following the procedure below.
1. Turn off the VAC and unplug the power supply plug.
2. Remove the power connector from the AC inlet
3. Remove the fuse holder by pulling out the depressed portion of the connection area for power
supply connector using a screw driver or the like.
[Fig. 11.1] Fuse holder
4. Replace the current fuse with the spare fuse.
Spare Fuse
Blown Fuse
[Fig. 11.2] Replacing fuses
5. Put the fuse holder back into the original position
Note:
In case the fuse blows again even after the blown fuse is replaced, the product may have problems.
Please contact your dealer.