![IDK HDC-TH200 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/idk/hdc-th200/hdc-th200_user-manual_3729898033.webp)
HDC-TH200 User Guide/Command Guide
33
8.3 Input
8.3.1 [ F16 ] No-signal input monitoring
If you change the EDID settings of the HDC or power the HDC off/on, the source device may not output a
video signal. Use this menu to set the monitoring time. This is the interval beginning when a source device is
not outputting a signal; and ending at the point when the HDC requests an output from that source device.
Changing EDID
ON
OFF
Requesting source device to
output video signal
Monitoring
Hot plug
ON
OFF
Video signal from
source device
[Fig. 8.2] Monitoring absence of input
Setting value
oFF
: OFF
02 to 15 : 2 sec. to 15 sec. [Default] 10 sec.
Notes:
If you are using the monitor power-saving or dual monitor features on your PC, set this feature to
“OFF”.
This will avoid potentially unpredictable operation.
When using this feature, ensure that the “monitoring time” is set for a value greater than the amount of time
needed for the source to provide an output signal.
[Fig. 8.3] Repeating output reset
Changing EDID
Monitoring
ON
OFF
Monitoring
Monitoring
Outputting source device
’
s video
Video signal from
source device
Requesting source device to output signal