Overview 

This manual pertains to the specified devices only and does not intend to replace or substitute for certified 
training in the application of this equipment.  The device is intended for qualified medical personnel who 
have been trained in the use of medical equipment. 

Owner Responsibilities 

The owner of this device is responsible to ensure system compatibility, the qualifications of the operator 
and maintenance personnel.  The operator must be properly trained and have obtained credentials from the 
appropriate authorities. 

This equipment must be installed in an area provided with the proper electrical power. 

The owner of this device is responsible for verifying continued compliance with all applicable regulations 
and standards.  Consult local, state, federal and/or international agencies regarding specific requirements 
and regulations applicable to the use of this equipment. 

Image  Diagnostics,  Inc.  certifies  only  the  equipment.  After-sale  operating  practices  and  safety  are  the 
responsibility of the owner and operator. Image Diagnostics, Inc. assumes no liability or responsibility for 
after-sale operating or safety practices; nor can it be responsible for personal injury or damage resulting 
from misuse. 

Never make modifications or adjustments to the equipment unless directed by a qualified Image Diagnostics 
representative.    This equipment,  when  properly  assembled, meets  US federal regulations and  standards.  
Unauthorized  modifications  to  the  equipment  may  impact  adherence  to  these  standards  and  make  the 
equipment unsafe to operate. 

Customer Support 

Image  Diagnostics  will  make  available,  on  request,  circuit  diagrams,  component  part  lists,  or  other 
information which will assist the user’s appropriately qualified technical personnel to repair those parts of 
equipment  which  are  designated  by  the  manufacturer  as  repairable.    The  information  provided  in  this 
manual may be updated at any time.  Customers may access the most current IFU documentation online at 
www.imagediagnostics.com. 

For technical assistance, call IDI at (978) 829-0009. Be prepared to give the complete model and serial 
number found on the data plate on the rear of the ilex base at the time of contact. 

Image Diagnostics, Inc. 

310 Authority Drive 

Fitchburg, MA 01420 USA 

Made in the USA 

 

This  video  integration  device  manufactured  by  Image  Diagnostics,  Inc.  complies  with  applicable  FDA 
performance standards contained in 21CFR at date of manufacture. 

 

Содержание ilex

Страница 1: ...USA L280 0688 REV C Mobile Video Integration System Operator Manual For units using IPS500A video signal router The text of this manual was originally written approved and published by the manufacture...

Страница 2: ...lity or responsibility for after sale operating or safety practices nor can it be responsible for personal injury or damage resulting from misuse Never make modifications or adjustments to the equipme...

Страница 3: ...ructions 9 Electronics Installation 9 Moving and Positioning 10 6 Instructions for Operation 11 System Components of the ilex 11 FSN Monitor Controls 11 Power Switches 13 Speakers 14 StableCable cable...

Страница 4: ...rectives and standards in effect within the European Union at the time of manufacture Alternating current Data plate with device serial tag Warning Information or instructions shown near this symbol m...

Страница 5: ...ound This is the common tie point between the AC cord ground frame ground and controller ground For safety and proper function of equipment connect power cord to a properly grounded outlet Model of de...

Страница 6: ...personnel operating the ilex system be familiar with the equipment operation transport and all documentation supplied by IDI The ilex system is intended to be used in typical clinical or research env...

Страница 7: ...pment Approach all obstacles slowly Operator must use a ramp to allow the casters to roll up and over the vertical edge for over 3 8 10mm WARNING It is the user s responsibility to make sure the equip...

Страница 8: ...other equipment EMC operating specifications for these tables can be located in the Specifications and Requirements section of this manual The equipment or system must be observed to verify normal ope...

Страница 9: ...shown above to allow room for the monitor when it is in the lowest position and to ensure easy access to controls Use caution when raising or lowering monitor to prevent collision with personnel wall...

Страница 10: ...and roll in any horizontal direction Steer Lock Step down on the left end of the caster brake pedal with the green dot to lock the direction of the two casters closest to the pedal making steering eas...

Страница 11: ...20in 50cm x 50cm 12in 31cm 9in 22cm 16in 40cm 92in 72in 233cm 182cm 301 2 77cm 31 790mm 55in 140cm ACROSS HANDLES 353 4 910mm ilex55 Mobile Video Display System IMAGE DIAGNOSTICS INC Emergency Stop M...

Страница 12: ...Operator Manual ilex with IPS500A L280 0688 REV C www imagediagnostics com Page 12 Please refer to FSN s User Guide accompanying the monitor for additional functionality and settings of the monitor...

Страница 13: ...the right side of the box and there is a power on off switch Under normal use these buttons can stay in the ON position On off Button use the green toggle switch thermal breaker to turn the system on...

Страница 14: ...ar the system prompt Paring 7 When a successful connection is established the LED indicator light on the cart will stay lit without blinking and you will hear the system prompt Your device is connecte...

Страница 15: ...ime the charging will taper off If the unit loses AC power the monitor elevation function will automatically switch to battery back up mode An audible tone is sounded when using an operator control fu...

Страница 16: ...leach in a solution of 5 25 sodium hypochlorite diluted between 1 10 and 1 100 with water o Alcohol generic o Envirocide Notes For the cleaning of monitor or shelf equipment please consult correspondi...

Страница 17: ...ics Instead apply the liquid to the cleaning cloth Follow your hospital protocol for the handling of blood and body fluids The display is not disinfected or packed in sterile environment Follow your h...

Страница 18: ...stened with a recognized cleaning product for medical equipment 2 Repeat with water only 3 Wipe dry with a dry cloth 4 Cabinet has been tested for resistance to the following products Virex Ready to u...

Страница 19: ...al equipment This individual must have access to this manual and the proper tools Lubrication of this device is not required RECOMMENDED PERIODIC PERFORMANCE CHECKS Daily Prior to use Inspect all exte...

Страница 20: ...nd aluminum which are easily recycled Some components can be disassembled before recycling COMPONENT ITEM RECYCLING GROUP Actuator Spindle and Motor Housing Cable Metal Steel and Copper Plastic Copper...

Страница 21: ...rrent Rating Less than 12 Amps 120 Vac or 7 Amps 230 Vac Isolation transformer limits leakage current to 50 Isolation transformer is certified to meet Medical Safety Standards ANSI AAMI ES60601 1 Envi...

Страница 22: ...rame with telescoping steel square tube supporting a 55 LED monitor 31 78 75cm wide x 29 73 66cm deep footprint of the base The height of the unit from the floor to the top of the monitor is 72 184cm...

Страница 23: ...mpliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are c...

Страница 24: ...he transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than th...

Страница 25: ...80 MHz __ d 1 2 P 80 MHz to 800 MHz __ d 1 2 P 800 MHz to 2 5 GHz __ d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 79 3 79 7 27 100 12 00 12 00 23 00 For transmitters rated at a...