![Idexx VetTest Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/idexx/vettest/vettest_operators-manual_3709626032.webp)
$o
IDEXX VetTest* Chemistry Analyzer Operator’s Manual
Urine Sample Volumes
5PSVOB6SJOF1$3BUJPZPVOFFEBNJOJNVNPGÚ-PGUIFTVQFSOBUBOU
Ú-JTVTFEUPQSJNFUIF7FU5FTUQJQFUUPS
t
Ú-JTEJTQFOTFEPOUPUIF6130TMJEF
t
Ú-JTOFFEFEUPQSFQBSFUIF6$3&TBNQMFVTJOHUIFTBNQMFQSFQBSBUJPOLJU
t
Note:
The IDEXX Urine Protein:Creatinine Sample Preparation Kit prepares the
sample for the urine creatinine test so the VetTest analyzer can calculate the most
accurate and quantitative UPC ratio result.
Urine Sample Preparation
To prepare a urine sample:
Obtain a urine sample through cystocentesis.
1.
$FOUSJGVHFUIFTBNQMFPOBiVSJOFwTFUUJOHGPSBTQJOUJNFPGTFDPOET
2.
Transfer the supernatant to an untreated collection tube or a sample cup using a
3.
VetTest transfer pipette (or any other pipette). During this process, it is important
that you do not aspirate any of the sediment, if present.
Run the UPRO slide on the VetTest analyzer.
While the UPRO test is running, use the sample preparation kit to properly
prepare the sample for the UCRE slide analysis. See the kit’s package insert
for instructions.
Run the UCRE slide using the prepared sample.
Note:
See the
Sample Storage
TFDUJPOPOQBHF$GPSTUPSBHFHVJEFMJOFT
Sample Storage
IDEXX recommends that you process and analyze samples immediately after collection
for best results. However, if storage is necessary, follow these sample storage and
testing guidelines.
Storing Serum or Plasma Samples
For storage, the serum or plasma must be separated and removed immediately from
the blood cells. Do not attempt to pour off the sample.
t 6TJOHBUSBOTGFSQJQFUUFDBSFGVMMZUSBOTGFSUIFTFSVNPSQMBTNBUPBOVOUSFBUFE
collection tube, taking care not to draw up any white or red blood cells.
t $BQUIFUVCFUJHIUMZUPBWPJEDPOUBNJOBUJPOBOEFWBQPSBUJPO"WPJEGSPUIJOHBUBOZ
stage as this damages the serum proteins.
If you cannot perform analysis within four hours of drawing and processing the sample,
SFGSJHFSBUFJUBU×o×$ ×o×'*GZPVDBOOPUQFSGPSNBOBMZTJTGPSNPSFUIBOIPVST
ZPVTIPVMEGSFF[FUIFTFSVNQMBTNBBU×$ ×'
Note:
For additional information on the effects of delays in removing serum or plasma
from the cells, see section
H: Chemistry Description and Guide
.
Note:
See the calcium (Ca
2+
), total bilirubin (TBIL), lactate (LAC), lactate
dehydrogenase (LDH), ammonia (NH
3
), and glucose (GLU) chemistry descriptions for
additional special handling and storage requirements.
Содержание VetTest
Страница 1: ...Operator s Manual IDEXX VetTest Chemistry Analyzer...
Страница 2: ......
Страница 4: ......
Страница 28: ...B 10 IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 34: ...o IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 52: ...o IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 56: ...o IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 96: ...J 2 IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 98: ...K 2 IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 130: ...M 2 IDEXX VetTest Chemistry Analyzer Operator s Manual...
Страница 131: ......
Страница 132: ...One IDEXX Drive Westbrook Maine 04092 USA idexx com 06 02247 05...