6.3.4.18. CNTLESS_NFC_SINGLESHOT
This Escape command is used to switch the device to Single-shot mode.
Input:
Offset
Description
Detailed description
0
0xEC
NFC Single-shot
1
0x01
NFC_DEP supported.
If a value other than 0x01 is given,
NFC_DEP is not supported in the
preceding I-Blocks.
Output:
Output buffer
NULL
6.3.4.19. CNTLESS_NFC_LOOPBACK
This Escape command is used to switch the device to Loop-back mode.
Input:
Offset
Description
Detailed description
0
0xED
NFC Loop-back
1
0x01
NFC_DEP supported.
If a value other than 0x01 is given,
NFC_DEP is not supported in the
preceding I-Blocks.
Output:
Output buffer
NULL