CLOUD
47
X
0
F
R
EFERENCE
M
ANUAL
77
6.3.4.21. CNTLESS_GET_P2P_EXTERNAL_RF_STATE
This Escape command is supported through the
READER_GENERIC_ESCAPE
message.
This command is used to check if external RF is reset after the reader got detected in target
mode.
Input:
Byte0
CLA
Byte1
INS
Byte2
P1
Byte3
P2
Byte4
Lc
Byte5
Le
0xFF
0x70
0x04
0xE6
0x01
0x06 (opcode) 00
Output:
If the command is successful, a single byte is returned. This byte indicates the value of
parameter.
Bit 0 => Set to logic 1, when a present external RF field is switched off
Bit 1 => Set to logic 1, when an external RF field is detected.
Bit 2 to Bit 7 => RFU bits always read as 0