5-4
IDEC SmartRelay User’s Manual
Parameterizing IDEC SmartRelay
5.1.3
Changing a Parameter
To change a parameter, you first have to select it (see
“Selecting a parameter”).
Change the value of the parameter in the same way you
entered it in programming mode:
1. Move the cursor to the point at which you want to make
the change:
or
2. Change the value:
or
3. Accept the value:
OK
B01:T
T
a
= 00:00m
To move:
or
To change value:
or
Finished: OK
T
=
0
1:00m
You cannot change the unit of the delay time for the
parameter T in parameterization mode. This is only
possible in programming mode.
Current value of a time T
If you view a time T in parameterization mode, it looks like
this:
You can change the set time T (see “Changing a
parameter”).
B01:T
T
a
= 00:00m
T = 12:00m
Time T set
Current time T
a