Functions
HR9Z-B2190 8/2020
59
Application Function 3
Synchronization:
Wiring of the inputs for coded magnetic switches
Characteristic
Value/Description
Typical applications
Monitoring of guards as per ISO 14119/14120
with electrical switches
Monitoring of guards as per ISO 14119/14120
with coded magnetic switches
Monitoring of proximity switches
Type of outputs of sensor/device providing the input signal
for application function
Normally open, normally closed and/or changeover
outputs
S## terminals to be connected
S11-S12 and S11-S13
Dynamization
Yes
Signal interlock monitoring
No
Synchronized terminals
Synchronization time
S12 synchronized with S13
S12 and S13 have to be activated within 0.5 s.