5: S
PECIAL
F
UNCTIONS
« FC4A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
»
5-9
Special Internal Relays for Two-phase High-speed Counter (Slim Type CPU Modules)
Note:
Special internal relays M8130 through M8132 and M8135 through M8137 go on for only one scan.
Special Data Registers for Two-phase High-speed Counter (Slim Type CPU Modules)
Two-phase High-speed Counter Specifications (Slim Type CPU Modules)
Single-phase High-speed Counters HSC1 through HSC4 (Slim Type CPU Modules)
HSC1 and HSC4 can also be used as a single-phase high-speed counter as well as HSC2 and HSC3. The four single-phase
high-speed counters count input pulses to the input terminal allocated to each high-speed counter. When the preset value is
reached, a designated comparison output turns on, and the current value is reset to 0 to count subsequent input pulses.
Two special data registers and four special internal relays are assigned to control and monitor the single-phase high-speed
counter operation. The current value is stored in a special data register (current value) and is updated every scan. The value
stored in another special data register (preset value) is used as a preset value. When a reset input special internal relay is
turned on, the current value is reset to 0.
The single-phase high-speed counter is enabled while a gate input special internal relay is on and is disabled while the gate
input is off. When the current value reaches the preset value, a special internal relay (comparison ON status) turns on in the
next scan. At this point, the current value is reset to 0, and the value stored in a preset value special data register takes
effect for the subsequent counting cycle. When a comparison output reset special internal relay is turned on, the designated
comparison output is turned off.
In addition, only the single-phase high-speed counter HSC1 or HSC4 has reset input I2 or I5 and reset status special inter-
nal relay M8130 or M8135. When reset input I2 or I5 is turned on to reset the current value to 0, reset status special inter-
nal relay M8130 or M8135 turns on in the next scan. When reset input special internal relay M8032 or M8046 is turned on,
M8130 or M8135 does not turn on. See page 5-14.
Description
High-speed Counter No.
ON
Read/Write
HSC1
HSC2
HSC3
HSC4
Comparison Output Reset
M8030
—
—
M8044
Turns off comparison output
R/W
Gate Input
M8031
—
—
M8045
Enables counting
R/W
Reset Input
M8032
—
—
M8046
Resets the current value
R/W
Reset Status
M8130
—
—
M8135
Current value reset by I2 or I5
Read only
Current Value Overflow
M8131
—
—
M8136
Over flow occurred
Read only
Current Value Underflow
M8132
—
—
M8137
Under flow occurred
Read only
Description
High-speed Counter No.
Updated
Read/Write
HSC1
HSC2
HSC3
HSC4
High-speed Counter Current Value
D8045
—
—
D8051
Ever y scan
Read only
High-speed Counter Reset Value
D8046
—
—
D8052
—
R/W
Maximum Counting Frequency
20 kHz
Counting Range
0 to 65535 (16 bits)
Operation Mode
Rotar y encoder (phases A, B, Z)
Gate Control
Enable/disable counting
Current Value Reset
Current value is reset to a given value when the current value over flows 65535 or
under flows 0, or when reset input I2/I5 or reset input special internal relay M8032/
M8046 is turned on.
Control/Status Relays
Special internal relays are provided to control and monitor the high-speed counter
operation.
Comparison Output
Any output number available on the CPU module can be designated as a comparison
output which turns on when the current value reaches the preset value.
Output numbers on expansion output or mixed I/O modules cannot be designated as a
comparison output.
Содержание FC4A-C10R2
Страница 1: ...FC4A SERIES Micro Programmable Logic Controller User s Manual FC9Y B812 ...
Страница 6: ...PREFACE 4 FC4A MICROSMART USER S MANUAL ...
Страница 94: ...2 MODULE SPECIFICATIONS 2 74 FC4A MICROSMART USER S MANUAL ...
Страница 184: ...6 ALLOCATION NUMBERS 6 20 FC4A MICROSMART USER S MANUAL ...
Страница 218: ...8 ADVANCED INSTRUCTIONS 8 8 FC4A MICROSMART USER S MANUAL ...
Страница 240: ...11 BINARY ARITHMETIC INSTRUCTIONS 11 8 FC4A MICROSMART USER S MANUAL ...
Страница 244: ...12 BOOLEAN COMPUTATION INSTRUCTIONS 12 4 FC4A MICROSMART USER S MANUAL ...
Страница 252: ...13 SHIFT ROTATE INSTRUCTIONS 13 8 FC4A MICROSMART USER S MANUAL ...
Страница 274: ...15 WEEK PROGRAMMER INSTRUCTIONS 15 8 FC4A MICROSMART USER S MANUAL ...
Страница 378: ...22 DUAL TEACHING TIMER INSTRUCTIONS 22 4 FC4A MICROSMART USER S MANUAL ...
Страница 386: ...23 INTELLIGENT MODULE ACCESS INSTRUCTIONS 23 8 FC4A MICROSMART USER S MANUAL ...
Страница 408: ...24 ANALOG I O CONTROL 24 22 FC4A MICROSMART USER S MANUAL ...