IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: [email protected]
User’s guide DLC4000/DLC8000 -
Doc. V2.1 - Firmware V3.1
7.
Page 9
8.
RJ45 - L=5m.
J2.1
J2.4
J2.3
J2.6
J2.5
J2.8
J2.7
J2.9
03
01
+
_
02
04
_
+
_
_
05
06
07
08
J2.2
B4
B3
B2
B1
B1
_
+V
B8
B5
_
__
__
__
__
_ _
_ _
_ _
_ _
+V
&
&
__
B7
B6
+
Only DLC8000
Load 5
Load 5
Load 5
Load 6
Load 7
Load 8
Load 8’
Load 4
Load 3
Load 2
Load 1
Wiring diagram
POWER
SUPPLY
(6 mm² max)
INPUTS
+10 to 28,5VDC
Positive input 1 «+ ignition »
Obligatory
Fuse (max 20A)
DLC4000/
Console
DLC8000
DLC4000/
Module
DLC8000
Technical characteristics
7.1. Console
7.2. Power module
Operating Voltage
Operating Temperature
Connection Type
Weight
Dimensions (L x W x D)
Automatic Backlighting
Multidirectional Foot Mounting
: +5VDC ±5% supplied by the module
: de -25°C à +60°C
: RJ45 (non-crossed)
: 115 gr.
: 95 x 70 x 35 mm (without the foot)
:
Operating Voltage
Operating Temperature
Number of positive outputs
Number of negative outputs
Maximum current. /positive output
Maxi. current /negative output
Maxi. current general
Type of output
Power module weight
Dimensions over all
: de +10 à +28.5VDC
: de -25°C à +60°C
: 4 for DLC4000 and 8 for DLC8000
: 2
:10A
: 2A
: 20A
: Static
: 80 gr.
: 94 x 73 x 26 mm
Negative input 2
Positive input 3
Load 7’