3
Response FF80
- Installation
PERFORMANCE DATA
Boiler
Response FF80
Gas supply type & connection
2H-G20-20mbar, Rc1/2
Inlet connection
Domestic Hot Water
15mm copper
Outlet connection
Domestic Hot Water
15mm copper
Flow connection &
Central heating
Return connection
22 mm copper
Flue terminal diameter
mm (in.)
100 (4)
Max. working pressure (sealed systems) bar (lb/in
2
)
2.65 (38.5)
Max. DHW water inlet pressure
bar (lb/in
2
)
10.0 (145.0)
Min. DHW water inlet pressure
bar (lb/in
2
)
0.5 (7)
Electrical supply & loading
230 V ~ 50 Hz, 160W max
External fuse rating
3A
Internal fuse rating
PCB 38 F1: T2A
PCB 38 F2: H2A
PCB 37 F1: H2A
Water content
Central Heating
litre (gal.)
2.3 (0.50)
Domestic Hot Water
litre (gal.)
0.48 (0.11)
Dry Weight
kg (lb.)
50 (110)
Boiler size
Height
mm (in.)
640 (25
3/16
)
Width
mm (in.)
436 (17
1/8
)
Depth
mm (in.)
278 (10
15/16
)
Table 1 - General Data
Table 2 - Performance Data - CENTRAL HEATING
Response FF80
Max
Min
Burner pressure (HOT)
mbar (in.w.g.)
8.3 (3.4)
3.7 (1.5)
Input based on nett CV
kW (Btu/h)
19.8 (67 500)
12.6 (43 000)
Input based on gross CV
kW (Btu/h)
22 (75 000)
13.9 (47 500)
Output
kW (Btu/h)
17.6 (60 000)
11.7 (40 000)
Gas consumption (Hot)
l/s (ft
3
/h)
0.568 (220)
0.359 (139)
Table 3 - Performance Data - DOMESTIC HOT WATER
Response FF80 (Maximum)
Burner pressure (HOT)
mbar (in.w.g.)
14.8 (5.9)
Input based on nett CV
kW (Btu/h)
26.4 (90 000)
Input based on gross CV
kW (Btu/h)
29.3 (100 000)
Output
kW (Btu/h)
23.4 (80 000)
Gas consumption (Hot)
l/s (ft
3
/h)
0.757 (293)
Flow 35
0
C. temp. rise
l/m (gpm)
9.6 (2.1)
Domestic hot water specific rate
l/m (gpm)
11.2 (2.4)
Key to symbols
IE
= Ireland
(Countries of
GB
= United Kingdom
destination)
PMS
= Maximum operating pressure of water
C13
= A room sealed appliance designed for connection via ducts to a
horizontal terminal, which admits fresh air to the burner and
discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream
of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross or
34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific
value:-
a. FOR L/S
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. FOR FT
3
/H
- divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.