19
Response FF80
- Installation
INSTALLATION
REAR FLUE OUTLET
18 CONNECTING THE TURRET TO THE BOILER
1.
Mate the turret to the flue.
2.
Secure the flue turret on top of the
boiler by inserting the open ends of
the turret clamp under the 2 studs
and fixing it in the middle with the
single M5 x 10mm pozi-hex screw
provided.
3.
Drill a 3.2mm hole through the flue
via the hole already present in the
turret. Secure the turret to the flue,
using the self tapping screw
provided.
4. Flues over 1 metre long.
Fix the flue support bracket to the
wall, using the wall plug and wood
screw.
•
For standard installations use
the short wood screw.
•
If the 'stand-off' option is used
secure the support bracket,
using the spacer bracket and
long wood screw.
17 MOUNTING THE BOILER
IMPORTANT
. This must not be
omitted.
6.
Engage and tighten the 5 pipe
unions.
7.
Fix the pressure relief valve
drain pipe to the pressure
relief valve, using the nut and
olive supplied in the hardware
pack.
1.
The boiler may be prewired to the loose electrical
connector and secured with the cable clamps. Refer
to Frame 39.
2.
Lift the boiler onto the wall mounting frame, locating
it over the tabs at the top of the frame.
3.
Lower the boiler into position.
4.
Remove plastic plugs and check that 'O' rings are in
position (spare 'O' rings in the hardware pack).
5.
Fit the filter to the DHW inlet valve as shown.