background image

22

21

- Option 1
This packet contains information on special measurement
modes. The format of this packet is shown below. The
three non-constant fields is set to one when the meter
operates in the corresponding special modes.

0

1

1

P

MAX

P

MAX

0

VAHZ

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

- Option 2
This packet contains information on the operations mode
of the meter. The format is shown below. The DC field
indicates that the meter operates in DC measurements
mode, either voltage or current. The AC field indicates that
the meter operates in AC measurement mode. The AUTO
field is set to 1 if the meter operates in automatic mode,
and is set to 0 when the meter operates in manual mode.
The APO field indicates whether Auto Power Off function is
enabled or not.

0

1

1

DC

AC

AUTO

APO

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

- CR
Carriage return. The transmitted code is 0001101.

- LF
Line Feed. The transmitted code is 0001010.

C

US

General Specifications

Display: 

The Liquid Crystal Display (LCD) 
with a maximum reading  of 4000 and
82 segments bar graph.

Polarity Indication: 

Automatic, positive implied, negative 
indicated.

Over range indication: 

(OL) or (-OL)

Low Battery Indication:

is displayed when the battery 

voltage drops below operating 
voltage.

Sampling: 

2 times/sec for digit. 
12 times/sec for analog bargraph.

Auto Power Off: 

Approx 30 Minutes

Operating Ambient: 

0°C - 30°C (

80%R.H.), 

30°C - 40°C (

75%R.H.), 

40°C - 50°C (

45%R.H.)

Temperature Coefficient: 0.15 x (Spec Acc’y) / °C, 

<18°C or >28°C.

Power Requirements:

IEC LR03, AM4 or AAA size 1.5V x 2.

Battery Life: 

Alkaline 500 hours.

Dimensions

(WxHxD):

90mmx200mmx42mm, 
with out holster
100mmx212mmx55mm, with holster

Accessories: 

Protective Holster, battery (installed) 
instruction manual, test leads.

Environmental Conditions

Indoor use.
Maximum Altitude: 

2000 Meter.

Installation Category: 

IEC 1010, 1000V Cat. II, 600V Cat. III

Pollution Degree:

2

Содержание ND 2385-1

Страница 1: ...D Data Acquisition 2 1 LCD Display 2 Rotary Function Switch 3 COM Input Terminal 4 V Hz Input Terminal 5 mA Input Terminal 6 A Input Terminal 7 Backlight Button 8 Hz Button 9 Peak H Button 10 Range Bu...

Страница 2: ...be performed on cir cuits capable of delivering greater than 500 Volts 2 To avoid electrical shock hazards and or damage to the meter Do not exceed the voltage ratings for the meter Use caution when m...

Страница 3: ...utton This function displays the differential between the actual measurement and the last value displayed before pressing the REL button Pressing the hold button while in this function stops the displ...

Страница 4: ...M over 1000M in 400mV range MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection 7 AC Volts Range Resolution Max Display Accuracy 400mV 0 1mV 400 0 1 5 8 40Hz 60Hz 4V 1mV 4 000 1 0 5 40Hz 500Hz...

Страница 5: ...V IR 100kA fuse for A input 10 MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection AC Current Range Resolution Max Display Accuracy Voltage Burden 40mA 1 A 40 00 1 0 5 300mV max 400mA 0 1mA 400...

Страница 6: ...pprox MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection 11 Frequency RPM Range Resolution Max Display Sensitivity Accuracy 4kHz 40kRPM 1Hz 30RPM 4 000 40 00 150mV Frequency 2 0 Hz 0 01 1 1 5V...

Страница 7: ...play Accuracy 4nF 1pF 4 000 3 0 10 40nF 10pF 40 00 3 0 5 400nF 100pF 400 0 4 F 1nF 4 000 40 F 10nF 40 00 400 F 100nF 400 0 4mF 1 F 4 000 5 0 20 40mF 10 F 40 00 In these two ranges the reading may be r...

Страница 8: ...reading 90 of full scale Noise generating fields may affect intervals MIN MAX Hz PEAK HOLD Data Acquisition 2 Continuity Check To Verify Continuity 1 A continuity test ensures that all circuit connec...

Страница 9: ...ng the rotary switch If the meter is Re Powered on by pushing key switch the LCD displays the saved state when meter auto power off itself pushing Hold key switch to disable the hold state The meter w...

Страница 10: ...is 1 if battery low condition is true OL indicates input overflow 0 1 1 Judge Sign BATT OL Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 19 Range This packet indicates the full scale range of the meter W...

Страница 11: ...CR Carriage return The transmitted code is 0001101 LF Line Feed The transmitted code is 0001010 C US General Specifications Display The Liquid Crystal Display LCD with a maximum reading of 4000 and 8...

Страница 12: ...state to state IDEAL INDUSTRIES INC Sycamore IL 60178 U S A 800 304 3578 Customer Assistance www testersandmeters com ND 2385 1 Made in Taiwan Maintenance Battery Installation or Replacement The 61 4...

Отзывы: