OPERATING INSTRUCTIONS
FULL-AUTO DIGITAL ELECTRICAL TESTER
PDT35
Safety Information
Never use the tester if it or its test leads appear damaged.
Never apply more than 600V DC or 600V AC rms. Between any terminal
and earth ground
When using the probes, keep your fingers behind the finger guards on
the probes.
Turn off power to the circuit under test before cutting, unsoldering, or
breaking the circuit. Small amounts of current can be dangerous.
Use caution when working with voltages above 60V DC or 30V AC rms.
Such voltages pose a shock hazard.
Automatic Operation
The tester automatically turns on when you short the two test probes or place
the probes across a complete circuit.
When turned on, the tester powers up in continuity mode. If a DC or AC
voltage greater than about 4.0V is present across the inputs, the tester
switches to DC or AC voltage mode.
The tester automatically shuts down after approx. 4 minutes of inactivity.
Continuity testing
Turn off circuit power before testing.
Beeper indicates shorts lasting 1 ms or longer.
SHORT
10K
OPEN
Measuring Voltage
Refer to Automatic Selection
DC Voltage (Volts DC>4.0V)
AC Voltage (Volts DC>4.0V)
600V
DC
maximum
600V
AC
maximum
50Hz to 400Hz
12V DC 220V AC
Specifications
Function
Range
Accuracy (%rdg. + digits)
V AC (50Hz~400Hz)
600V
+(2.9%+8)
V DC
600V
+(1.5%+2)
Continuity test: Audible threshold 0~10K
, Continuity beeper 2KHz.
Overload protection: AC/DC 600V
Dimension/wt.: 215x72x36.7mm/235g
Display
: Large 1999 count LCD display with function and high voltage
warning indication.
Maximum Voltage Between any Terminal and Earth Ground
:
600V DC; 600V AC rms, Over-voltage Category III
Safety
: Complies with EN61010-1:2001 for use in over-voltage CAT III
environments