INSTRUCTION MANUAL 

D

IGITAL 

M

ULTI 

M

ETER

 

2230A/2230B 

We  thank  you  very  much  for  your  purchasing  our 
POCKET  PERSONAL  DIGITAL  MULTIETER,  This 
model  is  a  most  Reliable,  high-precision  instrument, 
designed by our excellent technology. 
Before  you  use  your  new  instrument,  please  read  this 
Operators Manual completely and familiarize yourself   
Thoroughly  with  all  functions  and  connections,  With 
proper use and care your Digital Multimeter will give you 
years of satisfactory service. 

SAFETY RULES 

Always check to make sure that the function switch
is set to the proper position.

When  making  measurements,  CAUTION  as
dangerous  voltages  may  be  present  in  normally
safe areas.

Always  disconnect  the  circuit  under  test  prior  to
attaching test leads, as voltages may be present in
capacitors  even  when  the  main  power  is
disconnected

To  avoid  electrical  shock,use  CAUTION  when
working above 60V DC or 25V AC rms.

Make  sure  all  power  (AC  or  DC)  is  disconnected
(OFF) 

when 

making 

resistance 

(OHMS)

measurement.

Never make measurement with the battery cover of
battery case OFF.

Never fail to keep the maximum tolerable input.

The POCKET PERSONAL DMM is designed for low
voltage  applications.  The  measurement  should  be
limited to the circuit under 500V (AC/DC)

NEVER  use  this  meter  if  it  is  WET,  DAMP  or  has
con-densation on it or the probes.

When  making  measurements  MAKE  SURE  your
hands NEVER touch anything xecrpt the plastic part
of the probes.

SPECIFICATIONS   

Measuring method:Dual integration mode 
Display:3 -3/4 digital LCD reading of appprox 3260. 
Range:Auto ranging 
Polarity 

Automatic 

no 

indication 

for 

positive 

polarity,minus(-) sign for negative polarity. 
Overrange  indication:

“OL”  mark  indication  (Except 

AC/DC ) 
Sampling:2 times/s 
Low Battery indication 

“ ” mark is displayed when the 

battery voltage drops below operating voltage   
Auto  power  off  :The  meter  is  powered  off  15  minute 
later  after  the  last  operation  was  made  to  bring  back 
display ,please return the function switch to the OFF. 
Bar graph display 

Operational temperature :0

40

℃,

80%RH(max) 

Storage temperature :-20

℃~

60

,70%RH (max) 

Power consumption: 6Mw(TYP) 
Size:54(W)×108(H)×12(D)mm   
Weight:Approx 110g (include batteries and case ) 
Accessores:Batteris ,LR-44(1.55V)    2 

Hard cover case 

Instrument manual 

MEASUREMENT RANGES 

Note/Accuracy  specified  for  temperature  range  of 
23

±5

, 80%RH(max) 

function 

range 

resolution 

accuracy 

2230A 

2230B 

DCV 

300mV 

300mV 

0.1 mV 

±

(1.3% of rdg +2 digits) 

3V 

3V 

1 mV 

±

(0.7% of rdg +2 digits) 

30V 

30V 

10 mV 

±

(1.3% of rdg +2 digits) 

300V 

300V 

100 mV 

500V 

500V 

1 mV 

ACV 

3V 

3V 

1 mV 

±

(2.3% of rdg +5 digits) 

30V 

30V 

10 mV 

300V 

300V 

100 mV 

500V 

500V 

1 mV 

OHM 

300

Ω

 

300

Ω

 

0.1

Ω

 

±

(2.0% of rdg +4 digits) 

3K

Ω

 

3K

Ω

 

1

Ω

 

±

(2.0% of rdg +2 digits) 

30K

Ω

 

30K

Ω

 

10

Ω

 

300K

Ω

 

300K

Ω

 

100

Ω

 

3M

Ω

 

3M

Ω

 

1K

Ω

 

±

(6.0% of rdg +2 digits) 

30M

Ω

 

30M

Ω

 

10K

Ω

 

±

(10.0% of rdg +5 digits) 

300

Ω

 

300

Ω

 

0.1

Ω

 

0~2.000V 

0~2.000V 

1 mV 

±

(10.0% of rdg +2 digits) 

DCmA 

30mA 

 

10

μ

±

(2.0% of rdg +2 digits) 

300mA 

 

100

μ

ACmA 

30mA 

 

10

μ

±

(2.5% of rdg +5digits) 

300mA 

 

100

μ

DECSRIPTION OF PANEL 

Function switch 
Switch  for  changing  the  measurement  function  (

Ω  / ) 

for resistance,countinuity check. 
(VOLT)for voltage measurement 
( mA)for current measurement 
(OFF) for power OFF 

Отзывы: