4
Mexico Slimline RS & CF 3/40-3/50 - Users
1 BOILER CLEARANCES
Safety
It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation of
the boiler.
Gas Safety (Installation & Use) Regulations 1994,
amendments 1996 or rules in force.
In your own interest, and that of safety, it is the law that this
boiler must be installed by a registered installer, in accordance
with all national and local regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole
switch having a 3mm (1/8") contact separation in both
poles, or a plug and socket, serving only the boiler and
system controls. The means of isolation must be
accessible to the user after installation.
Important notes
a.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
b.
The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
c.
If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been corrected
by a CORGI registered installer.
d.
Inflammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours
must not be stored in the same room as the appliance.
e.
Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
TTB downdraught thermostat
(CF boilers only)
This appliance is fitted with a TTB downdraught thermostat for
added safety and protection. If this thermostat should operate
and switch off the appliance it is because the flue is subject to
downdraught, probably as a result of adverse wind conditions.
The TTB is an automatic reset thermostat which will reset once
wind conditions have returned to normal, subject to a built-in reset
delay in excess of 10 minutes.
The TTB is an IMPORTANT SAFETY DEVICE and MUST NOT
be put out of action or interfered with in any way.
The TTB is not a substitute for an independently mounted carbon
monoxide detector.
In cases of repeated or continuous shutdown a CORGI
registered person should be called to investigate and rectify the
condition causing this. Only the manufacturer's original parts
should be used for replacement.
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given in Table 1 MUST be complied
with, in order to maintain the safe running of the boiler.
Table 1
Minimum
Minimum
Boiler
A
or
B
A + B
mm (ins.)
mm (ins.)
CF 3/40
25
(1)
100
(4)
CF 3/50
25
(1)
100
(4)
RS 3/40
5 (
3/16
)
10
(
3/8
)
RS 3/50
5 (
3/16
)
10
(
3/8
)
Dimensions in mm (in.)
THE LOG BOOK SHOULD BE COMPLETED AFTER
EACH SERVICE AND KEPT WITH THESE
INSTRUCTIONS