background image

6

Mexico Slimline RS & CF 3/40-3/50 - Users

Boiler Overheat Thermostat

(Fitted for sealed systems only)

The boiler is fitted with a safety 'cutout' thermostat.  This
thermostat will extinguish the pilot and shut down the boiler in
the event of overheating. Should this occur, allow the boiler to
cool, press the reset button (E) on the overheat thermostat then
relight as detailed in steps 1-9 under 'To light the boiler'.

If the 'cutout' condition persists turn off the boiler and consult a
CORGI registered installer.

Loss of system water pressure

(Boilers fitted with the Overheat Thermostat Kit only)

If the red arrow on the system pressure gauge is set above zero
and the system pressure is seen to fall below this value over a
period of time then a water leak is indicated.  In this event a
CORGI registered installer should be consulted.

DO  NOT  FIRE  THE  BOILER  IF  THE  PRESSURE  HAS
REDUCED  TO  ZERO  FROM  THE  ORIGINAL  SETTING

Ideal Consumer Helpline: 01482 498660

CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:1994
Quality System accepted by BSI

CARADON PLUMBING Ltd.

 pursues a policy of continuing

improvement in the design and performance of its products. The
right is therefore reserved to vary specification without notice.

September 1999

151913 A02

CARADON PLUMBING Ltd

, P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN.

Telephone:  01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Registered
Office: National Avenue, Kingston upon Hull, HU5 4JN. 

A subsidiary of Caradon p.l.c

Escape of gas

Should a gas leak or fault be suspected, contact your gas
supplier 

without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
CORGI registered installer.

Note.

The appliance model is given on the data plate, located on the
front of the boiler base plate, behind the grille assembly.

The code of practice for the installation,

commissioning & servicing of central heating systems

Caradon Plumbing Limited is a member of the

Benchmark initiative and fully supports the aims of the

programme.  Benchmark has been introduced to

improve the standards of installation and commissioning

of central heating systems in the UK and to encourage

the regular servicing of all central heating systems to

ensure safety and efficiency.

THIS SYMBOL IS YOUR
ASSURANCE OF QUALITY

These appliances are designed for use with Natural
Gas only. They have been tested and conform with
the provisions of BS. 6332 and BS. 5258.

Содержание Mexico Slimline CF3/40

Страница 1: ......

Страница 2: ...es an easy to use programmer kit available on all models an overheat thermostat kit for all models and a pump kit that can be housed within the casing available for all models except the Super CF 3 14...

Страница 3: ...ppliance care should be taken when handling edges of sheet steel components Destination Countries GB IE Certified P I No CF 87 AT 15 Certified P I No RS 87 AT 14 Mexico Slimline CF 3 40 41 348 01 Mexi...

Страница 4: ...close proximity to the appliance Materials giving off flammable vapours must not be stored in the same room as the appliance e Under NO circumstances should any of the sealed components on this appli...

Страница 5: ...6 Summer conditions i e domestic hot water only The thermostat should be positioned at setting 2 These settings are offered for general guidance only and other settings may be found preferable depend...

Страница 6: ...er 1999 151913 A02 CARADON PLUMBING Ltd P O Box 103 National Ave Kingston upon Hull HU5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 Registered Office National Avenue K...

Страница 7: ...ice We ll be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us...

Страница 8: ...Please arrange for me to join an Ideal factory tour Range guides required The Ideal Guide a specifier s and installer s introduction to the Ideal domestic boiler range The Ideal Householders Guide to...

Отзывы: