background image

5

Mexico Slimline RS & CF 3/40-3/50 - Users

To light the boiler.

Refer to Frame 2

If a programmer is fitted refer to separate instructions for the
programmer before continuing.

1.

Check that the electricity supply to the boiler is OFF.

2.

Remove the lower front panel by pulling it forward and lifting
off.

3.

Open the control panel drop-down door and ensure that the
thermostat knob (A) is in the OFF position.

4.

Turn the gas control knob (B) to the RIGHT until resistance is
felt and then release it.

Wait for 3 minutes.

5.

Push in and retain fully depressed the gas control knob (B).
Press and release the ignition button (C) repeatedly until the
pilot flame can be seen through the sight glass (D). When
the pilot has lit, continue to press in the gas control knob (B)
for a further 15 seconds.

6.

Should the pilot go out at this or any other stage, turn the
gas control knob (B) CLOCKWISE and release it. Wait for 3
minutes then repeat instruction 5 - but wait longer than 15
seconds before releasing the gas control knob.

7.

Switch ON the electricity supply to the boiler and check that
all external controls, e.g. room thermostat etc., are ON.

8.

Turn the boiler thermostat knob (A) to position 6 and the
boiler will light.  Set the boiler thermostat to the desired
setting.

9.

Refit the lower front panel by locating the bottom edge
behind the top of the grille assembly and pushing the panel
backward to engage in the upper clips.

Winter conditions (i.e. central heating and domestic hot
water).

 The thermostat should  be positioned at setting 5 or 6.

Summer conditions (i.e. domestic hot water only).

 The

thermostat should be positioned at setting 2.

These settings are offered for general guidance only and other
settings may be found preferable, dependent upon the type of
system installed or as recommended by the installer.

To shut down the boiler

1. For short periods

Turn the boiler thermostat knob (A) to OFF. When heating is
again required, restore the knob to its original setting.

2. For longer periods

a.

Turn the boiler thermostat knob (A) to OFF.

b.

Turn the gas control knob (B) CLOCKWISE until
resistance is felt then release it  to extinguish the pilot
burner.

c.

Switch the electricity supply to OFF.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting.

For longer periods, the entire system should be drained -
including the domestic water supply.

If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
fitted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.

Control of water temperature

1.

Set the boiler thermostat knob (A) to give the required
temperature for central heating.

2.

The boiler thermostat automatically switches the main burner
OFF and ON to maintain the selected temperature.

3.

The pilot burner remains alight continuously to give re-
ignition of the main burner.

To relight the boiler

Repeat the procedure 1 - 9 detailed in 'To light the boiler'.

2 BOILER CONTROLS

RS boiler shown

LEGEND

A

Boiler thermostat knob

B

Gas control knob

C

Ignition button

D

Sightglass

E

Overheat thermostat (optional)
reset button

Содержание Mexico Slimline CF3/40

Страница 1: ......

Страница 2: ...es an easy to use programmer kit available on all models an overheat thermostat kit for all models and a pump kit that can be housed within the casing available for all models except the Super CF 3 14...

Страница 3: ...ppliance care should be taken when handling edges of sheet steel components Destination Countries GB IE Certified P I No CF 87 AT 15 Certified P I No RS 87 AT 14 Mexico Slimline CF 3 40 41 348 01 Mexi...

Страница 4: ...close proximity to the appliance Materials giving off flammable vapours must not be stored in the same room as the appliance e Under NO circumstances should any of the sealed components on this appli...

Страница 5: ...6 Summer conditions i e domestic hot water only The thermostat should be positioned at setting 2 These settings are offered for general guidance only and other settings may be found preferable depend...

Страница 6: ...er 1999 151913 A02 CARADON PLUMBING Ltd P O Box 103 National Ave Kingston upon Hull HU5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 Registered Office National Avenue K...

Страница 7: ...ice We ll be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us...

Страница 8: ...Please arrange for me to join an Ideal factory tour Range guides required The Ideal Guide a specifier s and installer s introduction to the Ideal domestic boiler range The Ideal Householders Guide to...

Отзывы: