![IDEAL Mexico Slimline CF3/40 Скачать руководство пользователя страница 4](http://html2.mh-extra.com/html/ideal/mexico-slimline-cf3-40/mexico-slimline-cf3-40_installation-and-servicing-manual_4195012004.webp)
4
Mexico Slimline CF 3/40 & 3/50 -
Installation
Mexico Slimline
INTRODUCTION
The Mexico Slimline
range
is of floor standing, conventional
flue gas boilers. They are range-rated to provide central heating
outputs of:
CF 3/40
8.8 kW (30,000 Btu/h) to 11.7 kW (40,000 Btu/h).
CF 3/50
11.7 kW (40,000 Btu/h) to 14.7 kW (50,000 Btu/h).
The boiler has a cast iron heat exchanger and is supplied fully
assembled, complete with a white enamelled mild steel casing.
The boiler thermostat control is located behind the upper front
panel (drop down door).
The boilers are suitable, as standard, for connection to open-
vented systems ONLY.
The systems may be:
z
pumped or gravity circulating indirect DHW only
z
pumped central heating only
z
pumped central heating combined with either a pumped or
gravity circulating indirect DHW circuit.
CONTENTS
Air Supply
. ......................................................................
7
Boiler Assembly - Exploded view
................................
9
Boiler Clearances
..........................................................
6
Burner Assembly - Exploded view
............................
34
Electrical Connections
...............................................
15
Electrical Diagrams
.....................................................
15
Electrical Supply
...........................................................
8
Fault Finding
...............................................................
31
Flue Connection
..........................................................
15
Flue Installation
.............................................................
7
Frost Protection
..........................................................
18
Gas Safety Regulations
................................................
5
Gas Supply
....................................................................
6
Initial Lighting
..............................................................
20
Installation
.....................................................................
9
Mandatory Requirements
.............................................
5
Pump
............................................................................
13
Servicing
......................................................................
22
Short List of Parts
.......................................................
32
System Electrical Diagrams
.......................................
17
Thermostatic Radiator valves
. .....................................
8
TTB Thermostat
. ...........................................................
7
Water Circulation
..........................................................
7
Water Systems
............................................................
13
Water Treatment
............................................................
8
B.G. Certified - P.I. No. 87 AT 15
Destination Countries: GB and IE
Natural Gas only
Appliance type: B
11
BS
Mexico Slimline CF 3/40
G.C. No. 41 348 01
Mexico Slimline CF 3/50
G.C. No. 41 348 03
OPTIONAL EXTRA KITS
Programmer Kit
Fits neatly within the casing. Separate
fitting instructions are included with this kit.
Overheat
Available to allow the boiler to be used
Thermostat Kit
on sealed water systems.
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.
Содержание Mexico Slimline CF3/40
Страница 1: ......
Страница 33: ...33 Mexico Slimline CF 3 40 3 50 Installation LIST OF PARTS 50 SHORT PARTS...
Страница 37: ...37 Mexico Slimline CF 3 40 3 50 Installation...