22
Mexico Slimline CF 3/40 & 3/50 -
Installation
26 SCHEDULE
SERVICING
SER
VICING
5.
Remove the 2 screws securing the control panel
and pull down to release the tabs from under the
top panel.
6.
Remove the thermostat phial from the pocket (as
shown) and unclip the TTB thermostat.
7.
If the boiler is not fitted under a work top, access
for flue cleaning will be improved by removing the
top panel.
27 BOILER CASING REMOVAL
1.
Lift off the lower front panel.
2.
Remove the 2 screws and lift off the grille assembly.
3.
Remove the gas valve electrical cover and
disconnect the electrical leads.
4.
Release the gas valve lead from the retaining clip.
e.
Check the condition of the thermocouple.
f.
Check that the flue is unobstructed and that the flue
system, including the flue cleanout cover, is sealed
correctly.
g.
If the appliance has been installed in a compartment,
check that the ventilation areas are clear.
The servicing procedures are covered more fully in Frames
28 to 32 and MUST be carried out in sequence.
WARNING.
Always turn OFF the gas supply at the gas
service cock and switch OFF and DISCONNECT the
electrical supply to the appliance
BEFORE SERVICING.
IMPORTANT.
After completing the servicing or exchange of
components always test for gas soundness and carry out
functional checks as appropriate and test for spillage.
To ensure the continued safe and efficient operation of the
appliance, it is recommended that it is checked at regular
intervals and serviced as necessary. The frequency of servicing
will depend upon the installation condition and usage but
should be carried out at least annually .
It is the law that any service work must be carried out by a
CORGI registered installer.
a.
Light the boiler and carry out a pre-service check, noting
any operational faults.
b.
Clean the main burner.
c.
Clean the heat exchanger.
d.
Clean the main injectors.
Содержание Mexico Slimline CF3/40
Страница 1: ......
Страница 33: ...33 Mexico Slimline CF 3 40 3 50 Installation LIST OF PARTS 50 SHORT PARTS...
Страница 37: ...37 Mexico Slimline CF 3 40 3 50 Installation...