Ideal Logic Combi -
Installation and Servicing
79 aLTERNaTING ‘L’ aND ‘6’ - FaLsE FLaME LOCKOUT
Reset the boiler, does Boiler Work OK?
NO
Check routing and integrity of internal boiler
wiring is OK. Check condition of Flame Sense
Electrode and replace if deteriorated.
Separate the flame detection electrode in-line
connector. Is there continuity between the terminals
pins connected to the electrode?
YES
Replace Flame Detection Electrode
YES
NO
Check routing and integrity of internal boiler wiring.
80 aLTERNaTING ‘F’ aND ‘1’ - LOW WaTER PREssURE
Are the Boiler and CH System filled with water and
all isolation and radiator valves open (check pressure
gauge is between 1 to 1.5 bar)?
NO
Fill and vent the system and open all isolation valves
YES
Are connections on water pressure sensor secure?
REsET PROCEDURE
- To reset boiler, turn mode knob to reset position and immediately turn knob back to required setting.
NO
Re-fit connections
Replace water pressure sensor
YES