16
Classic LX, RS -
Installation
Notes.
Pumped only
1.
Some earth wires are omitted for clarity. Ensure proper earth
continuity when wiring.
2.
Numbering of terminals on thermostats is specific to the
manufacturer.
3.
This is a fully controlled system - set the boiler thermostat to
maximum.
4.
Switchmaster 'Midi' is similar in operation but the wiring differs
slightly; see manufacturer's literature.
22 HONEYWELL 'C' PLAN
Notes.
Gravity HW & Pumped CH
1.
Some earth wires are omitted for clarity. Ensure proper earth
continuity when wiring
2.
Numbering of terminals on thermostats is specific to the
manufacturer.
23 FROST PROTECTION
INSTALLATION
INST
ALLA
TION
21 TWO SPRING CLOSED VALVES
Notes.
Pumped only
1.
Some earth wires are omitted for clarity. Ensure proper earth
continuity when wiring.
2.
Numbering of terminals on thermostats is specific to the
manufacturer.
3.
This is a fully controlled system - set the boiler thermostat to
maximum.
4.
Switchmaster valve has grey and orange auxiliary switch leads but
the grey wire must be connected to the live supply.
Central heating systems fitted wholly inside the house do not normally
require frost protection as the house acts as a 'storage heater' and can
normally be left at least 24 hrs. without frost damage. However, if parts
of the pipework run outside the house or if the boiler will be left off for
more than a day or so, then a frost 'stat should be wired into the system.
This is usually done at the programmer, in which case the programme
selector switches are set to 'Off' and all other controls MUST be left in
the running position. The frost 'stat should be sited in a cold place but
where it can sense heat from the system. Wiring should be as shown,
with minimal disturbance to other wiring of the programmer.
Designation of the terminals will vary, but the programmer and thermostat
manufacturer's leaflets will give full details. Diagram A shows a double
pole frost 'stat, which should suffice for all systems which do not use
the 'OFF' terminals of the programmer. Diagram B shows a 'change-
over' frost 'stat, which will cover most systems which do use 'CH OFF.'
If, however, on such a system the HW pipework is in an isolated part of
the house, a second frost 'stat may be used to protect it. If in doubt,
ask your installer for advice.
b
blue
gy
grey
g/y
green/yellow
LEGEND
b
blue
bk
black
w
white
gy
grey
g/y
green/yellow
br
brown
r
red
or
orange
LEGEND
b
blue
bk
black
g/y
green/yellow
gy
grey
br
brown
r
red
w
white
or
orange
20 MID POSITION VALVE
LEGEND
w
white
r
red
bk
black
br
brown
or
orange