N12966
Battery Replacement:
• Ensure test leads are disconnected from circuit or components.
• Remove test leads from input jacks on tester.
• Remove the two screws from the back case.
• Remove the back case.
• Replace battery with a new 9V battery.
• Assemble the back case to the tester and re-tighten the screws.
Fuse Replacement:
Unscrew the back cover, replace fuse(s) with the same type fuse (5 x 20mm, 200mA/250V). Screw the cover back
into place.
Maintenance:
Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
Service and Replacement Parts:
This unit has no user-serviceable parts.
For replacement parts or to inquire about service information contact IDEAL INDUSTRIES, INC at (877)-201-9005 or
visit our website www.testersandmeters.com.
SPECIFICATIONS:
Nominal Voltage for Phase Presence Indication:
100 - 600VAC (10-400Hz)
Phase Rotary Field Direction:
1– 600VAC (2-400Hz)
Determination of Motor Rotation (requires > ½ turn): 1-600VAC (2-400Hz)
Over Load Protection:
550V (between all terminals)
Fuses:
5 x 20mm, 200mA/ 250V fuse
Low Battery Indicator:
The “ OK” LED unlights when battery voltage
drops below operating level.
Battery:
(1) 9V, IEC 6LR61
Current Consumption:
Max 18 mA.
Size:
6.0”Hx2.8”Wx1.4”D (151mmHx72mmW x 35 mmD)
Weight:
6.4oz (181g) including battery
Display:
Neon Lamps and LEDs
Accessories included:
Carrying Case, Alligator Clip Leads, (1) 9V battery,
operating instructions.
Operating Temperature Range:
5ºF to 131ºF (-15°C to + 55°C)
Storage Temperature:
-4ºF to 158ºF (-20°C to + 70°C)
Safety:
Cat III – 600V
Double Insulation
Instrument has been evaluated and complies with insulation category III (overvoltage category III). Pollution degree
2 in accordance with IEC-644. Indoor use.
3