Page 7 of 17    5/11/2012 

e.

 

Enter 5143631030 

DEL./PAUSE

(hold for 2 seconds until the letter F 

appears on the screen, then enter

 230. 

f.

 

Press 

ARM/DISARM

 button to confirm. 

g.

 

Press 

PROG

  button eight (8) times to exit set-up mode. 

 
 
 

6. TO PROGRAM SIREN ON/OFF

 

The auto-dialer has been factory pre-set with the siren ON. To change this to OFF: 

     

 

a.

 

Enter password followed by 

PROG

  button four (4) times. 

b.

 

The " 

  " icon will flash on the auto-dialer screen. (Fig.8) 

c.

 

Press 

ARM/DISARM

 to confirm. 

d.

 

Using 

*/UP

 or 

#/DOWN

  buttons to select SOUND OFF. Followed by 

ARM/DISARM

 button to confirm. 

e.

 

Press 

PROG

  button six (6) times to exit the set-up mode. 

 

7.

 

TO PROGRAM AUTO CALL FUNCTION ON/OFF

 

The auto-dialer has been factory pre-set with the call option ON. If you do not want the 
auto dialer to call out change this to OFF: 

 

 
 

a.

 

Enter password followed by 

PROG

  button five (5) times. 

b.

 

The " 

    " icon will flash on the auto-dialer screen. (Fig.9) 

c.

 

Press 

ARM/DISARM

 button to confirm. 

d.

 

Using 

*/UP

 or 

#/DOWN

 buttons to

 

select call OFF followed by the 

ARM/DISARM

 button to confirm. 

e.

 

Press 

PROG

  button five (5) times to exit the set-up mode. 

 

8. TO PROGRAM AUTO DIALLING CYCLE

Содержание SK633

Страница 1: ...618 AUTO DIALER 1 629 REMOTE CONTROL 2 625 SLIM WINDOW DOOR CONTACT 1 6616 MOTION DETECTOR Batteries and all connecting devices Before permanently installing any of the devices included in this packa...

Страница 2: ...answering machine is the first response IMPORTANT SAFETY TIPS 1 Do not install the system where it will be exposed to direct sunlight or rain 2 The built in siren is very loud never put the system clo...

Страница 3: ...ng cycle how many times the auto dialer will dial each programmed number Records up to five triggered alarms for alarm mode Built in flash memory to protect system data during a power failure If you h...

Страница 4: ...e line can now be inserted into the telephone line splitter Fig 3a b 7 Connect the AC adaptor to the DC 9V jack on the auto dialer Fig 3c 8 Wall mount option Choose a suitable location where you have...

Страница 5: ...You now have the factory pre set password of 0 0 0 This will reset the password ONLY all other information will remain programmed telephone numbers and learned sensors 2 SETTING THE TIME YEAR MONTH DA...

Страница 6: ...o exit the set up mode 4 TO DELETE A TELEPHONE NUMBER FROM MEMORY a Enter password followed by PROG button twice 2 b MEMORY will flash on the auto dialer screen Fig 6 c Press ARM DISARM button to conf...

Страница 7: ...to confirm d Using UP or DOWN buttons to select SOUND OFF Followed by ARM DISARM button to confirm e Press PROG button six 6 times to exit the set up mode 7 TO PROGRAM AUTO CALL FUNCTION ON OFF The a...

Страница 8: ...followed by the ARM DISARM button to confirm e Press the PROG button three 3 times to exit set up mode NOTE You cannot use an answering machine with this feature If you want to be able to call in to t...

Страница 9: ...also adjust the sensitivity from 10m to 3m range by turning the dial located on the bottom of the unit under the battery cover Note If range and sensitivity is set too high it could result in false t...

Страница 10: ...or the contact on the door or window to be protected Determine location for the wireless sensor transmitter How much space is available will determine weather you install the transmitter on the door w...

Страница 11: ...s Press the HOME button on the side of the auto dialer wait 60 seconds at which time you will hear a beep Then trigger the wireless sensors The auto dialer will receive a signal and a chime will sound...

Страница 12: ...screen to confirm that the Auto Dialer has been DISARMED NOTE In the 24HR zone the sensors will trigger the auto dialer in ARM or DISARM mode and start dialing the numbers stored for the amount of tim...

Страница 13: ...ong password or operation code the call will disconnect and sound 5 beeps on the auto dialer If the call was an alarm call to you in which case you can wait for it to call you again providing you have...

Страница 14: ...er password followed by pressing the Home button b Zone one will flash on the LED screen c Using the UP and DOWN buttons select the zone you want to change the setting for d Press ARM DISARM button to...

Страница 15: ...screen FIG 7 c Press ARM DISARM to confirm the system will go into learning ID code mode and zone 1 icon will flash d Press the UP and DOWN buttons to select the zone you wish to learn your sensor to...

Страница 16: ...r on the back of the siren Use a pen to press and hold down the LEARN button for 2 seconds you will hear a beep Release the button The unit is now ready to receive the learn ID code signal from the au...

Страница 17: ...ows are pointing towards each other TIPS 1 Make sure the full telephone number has been entered correctly 2 Only suitable for single phone line Not compatible with fax machines or multi line telephone...

Отзывы: