SignalTEK NT
156875 Iss 3
User Guide
Page 10
Getting started
Press the soft key DETECT (F1) and the Near-End Unit will determine the mode of operation
dependent on the services detected. The display will show a home screen with one of four
connection symbols. There are two modes of operation, Cable and Ethernet. Cable has one
way of connecting, Ethernet has three.
Modes of Operation
Cable
Cable mode is used for Wiremap testing and
cable route tracing using the tone generator.
When the Near-End Unit is connected to a
copper cable, with or without an Active Remote,
press the soft key DETECT (F1) to display all
options available from the Cable mode screen.
When an Active Remote is connected it will be
shown on screen (Fig 7) and its identification
number displayed. For a full description of
these options, see
Fig 7
Ethernet
Fig 8
Ethernet mode is used for a range of IP and
performance tests. There are three ways
to connect in Ethernet mode:-
(1)
When the Near-End Unit and Remote
Unit are directly connected, with copper or
fiber cable, press the soft key DETECT (F1)
to detect all options available (Fig 8). In
addition to wiremap tests (copper), cable
performance can be tested and measured.
For a full description of these options see
Tests menu description – Ethernet mode,
page 25.