![IDEAL INDUSTRIES UniPRO MGig1 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/ideal-industries/unipro-mgig1/unipro-mgig1_user-manual_617145061.webp)
UniPRO
152810
User Guide
Page 61
Specifications – UniPRO MGig1 and UniPRO SEL1
The specifications listed below are for the MGig1 Duo PRO. To confirm the functionality of other models
refer to the
Functional overview table on page 9.
Term
Description
Test interface
RJ45: 10, 100, and 1000 Mb/s. Optical: 1000Mb/s with auto-negotiation and
optional SFP. UniPRO MGig1 Solo and UniPRO SEL1: x1 port. UniPRO
MGig1 Duo: x2 ports.
Operation mode
End point (terminated), pass through (monitor) for UniPRO MGig1 Duo only.
SLA-Tick
Items: frame loss, jitter (delay variation), delay (latency, loop test only), service
disruption time, information rate, error performance (SES, unavailability).
Mode: single-ended with remote loop or double-ended two way test. Tests up
to eight configurable services (streams) simultaneously with parameters on
each service, pass/fail limits, error injection: single, rate with frame.
RFC2544
Items: throughput, latency, frame loss, jitter, back to back, system recovery.
Table and graph results, frame size. Mode: single end loopback test or double
end Bi-Directional test. Pass/fail limits.
Y.1564 (NetSAM)
Configuration test on CIR (Committed Information Rate), EIR (Excess
Information Rate), color mode, traffic policing. Performance test up to 8
services simultaneously on utilization, FTD (delay), FDV (jitter), FLR (frame
loss), SES, availability measurement with fixed or mixed frame size, loop or Bi-
Directional test, pass/fail limits.
BERT
BER at L1 to L4 frame payload, test pattern on PRBS ITU or
Non ITU @ 2n-1 n=11,15,20,23,31. SCRTPAT, CRPAT,CJTPAT, CSPAT,
LFPAT, HFPAT, MFPAT, fixed: all 1s, 0s, 1100,1000, 1010. Word: 4 digit Hex,
Control: manual or user defined duration. Error injection: single, rate on frame
or bit.
Multi services (streams) Up to eight services simultaneously generated and measured on FLR, FTD,
FDV, IR with independent IP, MAC, VLAN, MPLS, TCP or UDP ports setup on
each service for SLA-Tick, NetSAM (Y.1564) test.
Target finding & remote
loop control
Auto detection of target devices (IDEAL NETWORKS’ products only) with
remote control of loopback (L1 to L4) via in band Ethernet test link. Targets
can also be manually controlled locally.
Traffic generation
Profile: continuous, ramp (service one only), burst (service one only).
Information rate, frame size, test pattern.
Frame size (byte)
64,128, 256, 512, 1024, 1280, 1518, user defined up to 10000.
VLAN
Level: up to eight including QinQ. VLAN ID, TPID, CFI, on each service.
MPLS
Level: up to three. Label, Class, TTL for each service.
MAC, IP & payload
Setup: MAC address, IP address: static, DHCP. DNS, netmask, gateway.
Version: IPv4, IPv6. CoS: ToS, DSCP.Payload: UDP & TCP ports, ICMP type
& code.
Service Disruption Time
(SDT)
Service protection switch time measurement (SDT) on each service with
resolution 1ms.
Error insertion
Items: FCS, oversize, undersize, pattern. Type: single, ratio.
MAC frame statistics
Per service based - Rx frame rate, Rx information rate, Rx frame size, Tx/Rx
frame counts, Tx/Rx layer payload accumulated byte count. VLAN ID, per port
based - frame type: unicast, multi cast, broadcast. Pause frames. Protocol
discovery: LLDP / CDP / EDP. Frame errors: collision (10/100Mb/s only),
FCS, undersize, oversize, jabbers, errored, % errored.