17
Installation and Servicing
Section 2 - Installation
INST
ALLA
TION
2.7 FLUES AND LOCATIONS
This installation & servicing manual must be read in conjunction with flue kit and fitting guide.
Flue deflector
Ideal part no.
208176
Flue extension
0.5 m, 1 m or 2 m
Weather collar
flat roof
Ideal part no.
152259
Ideal part no.
203130
Flue elbow 90°
Ideal part no.
203131
Flue elbow 45°
Horizontal flue
0.6 or 0.8 m
Ideal part no.
0.5 m 208169
0.7 m 208174
Telescopic
horizontal flue
0.5 or 0.7 m
Ideal part no.
211039
Vertical flue
terminal and
connector
Weather collar
Ideal part no.
152258
Ideal part no.
0.5 m 211037
1 m 203129
2 m 211038
Balcony flue kit
Ideal part no. 208177
Soffit kit
Ideal part no. 211302
Raised horizontal flue kit
Ideal part no. 208290
pitched roof
0.6 m 208171
0.8 m 217442
Ideal part no.
WARNING:
•
It is critical that products of combustion cannot re-enter
the building.
•
The flue terminal must always have a free passage of
air.
CAUTION:
• White sections of the flue must not be visible outside
.
• Install a flue terminal guard where the flue terminal is less
than 2 metres above a platform where persons can walk
or come into contact with the terminal.
• Water is the only permitted lubricant for flue assembly.
Rubber
Terminal
Wall Seal
Terminal
MUST be
fitted as
shown