![Ideal Boilers Minimizer FF 30 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/ideal-boilers/minimizer-ff-30/minimizer-ff-30_installation-and-servicing_617043020.webp)
Minimiser
- Installation
20
General arrangement
Note.
Side flue shown
1.
A
maximum
of two extension ducts (plus
the standard flue duct) may be used
together.
2.
Flue extensions of greater length than 1m
(39") should be supported with the bracket
provided.
INSTALLATION
This plate allows neat concealment and full compression of the
rubber seal. Its use is not essential if the flue hole and flue
ducts have been accurately cut and the outside wall face is flat.
1.
Position the terminal wall plate over the terminal.
2.
Drill 4 fixing holes with a 7mm (
1/4
") masonry drill.
3.
Insert the 4 plastic plugs provided.
4.
Secure the plate with 4 of the No.10 x 2" screws provided.
Note.
If the terminal is less than 2m (6' 6") above ground level,
an approved terminal guard should be fitted. Refer to the Flue
Installation, Page 5.
30 TERMINAL WALL PLATE
31 FLUE EXTENSION DUCTS - For flue lengths greater than 600mm
32 FLUE EXTENSION DUCTS - continued
Use a maximum of two extension ducts only
PACK D FLUE EXTENSION DUCT KIT CONTENTS.
INST
ALLA
TION