Time Controller Series User Manual
Section 8: Time Controller Configuration
ID QUANTIQUE SA
1227 Geneva
T +41 22 301 83 71
66
Rue Eugène-Marziano 25
Switzerland
F +41 22 301 83 79
8.2.1
Logical Blocks
8.2.1.1
Start (STAR)
There is one start block.
The STARt block receives the signal from the START channel. The signal can be simply as it is to the
next block (UNSHaped) or modified to be a short pulse of 5 ns corresponding to the event (SHAPed).
The STARt block is also able to receive a signal generated internally (from another block) by selecting
LOOP.
8.2.1.2
Input (INPU)
There are four input blocks, labelled from 1 to 4.
The INPUt block receives the signal from its corresponding input channel. The signal can be
transmitted as it is to the next block (UNSHaped) or modified to be a short pulse of 5 ns
corresponding to the event (SHAPed).
The INPUt block is also able to receive a signal generated internally (from another block) by selecting
LOOP or can receive the signal from the output of the same index. The mode can be switched
between high resolution (HIRES) or high speed (LOWRES).
8.2.1.3
Delay (DELA)
Signals from INPUt blocks are fed through a DELAy block before further processing.
Delay the linked signal by a user-configurable value.