background image

 

ELT-KLED 

Protege EliteSuite Icon LED Keypad 

  | November 2013

 

 

Fast Stay Arming __________________________________________________________________ 12

 

Switching From Stay to Regular/Force Armed _________________________________________ 12

 

Force Arming ________________________________________________________________________ 12

 

Force Arming Your System __________________________________________________________ 12

 

Bypassing Zones _____________________________________________________________________ 12

 

Bypassing Zones __________________________________________________________________ 12

 

Bypass Zone Recall ________________________________________________________________ 13

 

One Key Arming ______________________________________________________________________ 13

 

Special Features ______________________________________________________________ 14

 

Alarm Memory _______________________________________________________________________ 14

 

Viewing Alarm Memory _____________________________________________________________ 14

 

Clearing Alarm Memory _____________________________________________________________ 14

 

Chime Zones ________________________________________________________________________ 14

 

Chiming Zones ____________________________________________________________________ 14

 

Disable Audible Output ________________________________________________________________ 14

 

Disabling Audio Output _____________________________________________________________ 14

 

Messages ___________________________________________________________________________ 15

 

Panic Alarm __________________________________________________________________________ 15

 

Fire Alarm ___________________________________________________________________________ 15

 

Configuration _________________________________________________________________ 16

 

Zone Description _____________________________________________________________________ 16

 

Fire Zone ____________________________________________________________________________ 16

 

One Key Arming ______________________________________________________________________ 16

 

Panic Keys __________________________________________________________________________ 16

 

Timers ______________________________________________________________________________ 17

 

Users _______________________________________________________________________________ 17

 

Warranty _____________________________________________________________________ 18

 

Contact ______________________________________________________________________ 19

 

  

Содержание Protege EliteSuite

Страница 1: ...ELT KLED Protege EliteSuite Icon LED Keypad User Manual...

Страница 2: ...hotocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured...

Страница 3: ...uress Code__________________________________________________________________________ 8 User Setup ____________________________________________________________________ 9 Programming User Codes ________...

Страница 4: ...___________________________________ 14 Chiming Zones ____________________________________________________________________ 14 Disable Audible Output_____________________________________________________...

Страница 5: ...elegant and user friendly EliteSuite keypad maintains complete control of your residence providing easy to understand information All actions performed in your security system are executed and displa...

Страница 6: ...have been enabled Indicator Lights The keypad features several status indicator lights showing the condition of the system Power Trouble Input Ready Armed Alarm Bypass Install Message Indicator Light...

Страница 7: ...ch programmed zone by lighting the corresponding number on the display The 3 status options shown are FLASHING CONTINUALLY The zone is operating incorrectly Contact your building manager or security c...

Страница 8: ...is a master code for your system A master code can perform the arm or disarm functions modify and delete any user code change user options and modify user card numbers Other users may be given a maste...

Страница 9: ...quickly Confirm the user code by pressing USER CODE ENTER If correct the confirmation tone will sound and the ARMED LED will return to a slow flash If incorrect a rejection tone will sound and the co...

Страница 10: ...that can occur in your system are TROUBLE 8 Host Comms Communication with the host system is currently offline This is possibly due to maintenance or a system fault Contact the property manager or sec...

Страница 11: ...rm enter your USER CODE This will also disarm the system if it was armed Disarming Your System 1 Enter through a designated entry point Entry Door the entry delay time will start and the keypad will e...

Страница 12: ...ming and the motion detector is programmed as a force zone the system will allow you to arm even if the zone is open Force Arming Your System 1 Check that all zones that are not force zones are closed...

Страница 13: ...r USER CODE 2 Press and hold the BYPASS key for 2 seconds the last settings will be loaded You may change these settings if required 3 Press the ENTER key to store the bypass settings and exit 4 Press...

Страница 14: ...ate an audible tone every time that the zone opens The chime feature is ideal for a front door Chiming Zones 1 Login to the Setup menu and press MENU 1 2 Toggle chime mode on any zone by pressing the...

Страница 15: ...1 and 3 for the panic alarm Press and hold keys 4 and 6 for a medical alarm Press and hold keys 7 and 9 for a fire alarm i All Panic Alarm activations must be enabled by your property manager or insta...

Страница 16: ...NAME FORCE STAY BYPASS 01 ZONE 1 02 ZONE 2 03 04 Fire Zone The following lists the fire zone configuration for your system Enabled Disabled Fire Zone Delayed Fire Zone Your fire zone is located on zon...

Страница 17: ...programmed to be 30 seconds This is the time that you have to exit before the system arms If an alarm occurs the siren beeper will activate for 05 minutes unless disarmed Users The following table sho...

Страница 18: ...cts and because the products may be used in conjunction with products not manufactured by ICT ICT cannot guarantee the performance of the security system ICT s obligation and liability under this warr...

Страница 19: ...n below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 11 Canaveral Drive Albany North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124 Toll Free...

Страница 20: ...227 4125 101...

Отзывы: