Auto Sentry®
flex
User Manual
42
Introduction
The Deterrent Break-in Alarm settings are configured in WashConnect through the System Setup/
Devices/Settings/TouchConfiguration/Vandalism Deterrent Settings: Deterrent Break-In Alarm
Output 1 and 2.
In order to install the Electronic Vibration Detector, WashConnect needs to be on version 1.4.5.1 or
later. Contact ICS technical support to see if you can update WashConnect and install the
Electronic Vibration Detector.
In addition to the video, and up to two fired outputs, you can configure the system to send a
Critical email Alert via WashConnect. The email would post an Event Code of 2001e when the
alarm is triggered. The received Critical alert email message reads: VANDALISM ALARM IS ON –
NEEDS IMMEDIATE ATTENTION.
Vandalism Sensor
Guard your Auto Sentry with the Vandalism Sensor. The Seismic Detector needs to be installed
inside the top of the Auto Sentry. The Seismic Detector is wired to the SIO or PIO board. When the
Seismic detector senses tampering of the unit, the VandalismAlarm.avi video plays on the Auto
Sentry screen. This is known as the Break-In alarm.
The Seismic detector will also fire up to two outputs. The outputs may control lights, horns, or may
provide a signal to the alarm company’s monitoring system to notify authorities of the warning.
The Vandalism Warning parameters are configured in WashConnect through the System Setup/
Devices/Settings/TouchConfiguration/Vandalism Deterrent settings: Deterrent Break-In Alarm
Output 1 and 2.
Table 2: Auto Sentry Vandalism Deterrent
Field
Description
Deterrent Alarm Output
Numeric. The output that will be fired when the alarm is tripped.
Deterrent Alarm Time Out
Numeric. Minutes. If set to zero, the alarm never resets based on this
timeout. Any number entry greater than zero represents the time to
wait (in minutes) until the alarm is automatically reset.
Deterrent Disarm Alarm Time Out
Numeric. Seconds. How long the alarm stays off after you press the
Disable Alarm button in the Service Unit diagnostics screen.
Deterrent Enable
True
or
False
. Enable or disable the vandalism alarm.
Deterrent On Change Low High
Type
HIGH
if the alarm triggers on a logic change from low to high.
Else, type LOW.
Содержание Auto Sentry flex
Страница 1: ...User Manual Version 2 0 Auto Sentry flex ...
Страница 14: ...Auto Sentry flex User Manual 14 List of Figures ...
Страница 33: ...Auto Sentry flex User Manual 33 Introduction Figure 16 Moneris Card Reader bottom of unit ...
Страница 34: ...Auto Sentry flex User Manual 34 Introduction Figure 17 Credit Card Reader face ...
Страница 72: ...Auto Sentry flex User Manual 72 Operating Figure 48 Wash Purchase and Extra Service with Club Card 1 2 3 4 ...
Страница 74: ...Auto Sentry flex User Manual 74 Operating Figure 49 Wash Purchase with Club RFID Tag 3 5 1 2 4 ...
Страница 92: ...Auto Sentry flex User Manual 92 Operating ...
Страница 112: ...Auto Sentry flex User Manual 112 Service Unit Screen ...
Страница 114: ...Auto Sentry flex User Manual 114 Marketing with your Auto Sentry Figure 78 Custom Button Enabled for PLU 5 ...
Страница 166: ...Auto Sentry flex User Manual 166 Marketing with your Auto Sentry ...
Страница 168: ...Auto Sentry flex User Manual 168 Reports Figure 123 Shift Detail Report Page 1 ...
Страница 169: ...Auto Sentry flex User Manual 169 Reports Figure 124 Shift Detail Report Page 2 ...
Страница 188: ...Auto Sentry flex User Manual 188 W Wash busy 91 Wash code expired 89 not valid 89 ...
Страница 190: ...Auto Sentry flex User Manual 190 ...