![ICS 8099 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/ics/8099/8099_instruction-manual_3540995030.webp)
2-10
2
6.
When the server(s) have been found, use the pulldown arrow in the
Found Servers box to view the Found Server addresses. The card’s
default address is 192.168.0.254. Highlight the card’s IP address and
click the
Create Link
button. If the server is not found, you can enter
the default IP address (192.168.0.254) or the host name in the Found
Servers box. Click the Create Link button.
7.
When the link has been created, device model number(s) will appear
in the ‘Select Device to be Configured’ box. Highlight the desired
model number and click the
Configure
button to start the configuration
process.
8.
The Configuration Choices box displays only one line with the first
parameter to be changed and its current setting. If you like the current
setting, click
Enter
to advance to the next parameter. If you want to
change the setting, type a new value in the New Value box and click
Enter
. The program will send your setting to the card and read back
the new setting. Repeat as needed to make another change or click
Enter
again to advance to the next parameter.
9.
Repeat step 8 for each configuration parameter. Figure 2-9 shows the
VXI-11 Configuration Utility after all parameters have been entered
for a Model 8099. Click the
Redo From Start
button if you need to
start over or if you want to change any of the prior settings
10.
When done, the
Save Configuration
button is enabled if you changed
any settings. Click the
Save Configuration
button to save the values
in the card’s flash memory.
If you did not make any changes you can just exit the program.
11.
The unit has to be power cycled or rebooted before the configuration
changes take affect. Click the
Reboot
button to reboot the card and
use the new settings.
12.
Press the
Exit
button to quit the VXI11_config program.
13.
If the IP address was changed to an address outside the 192.168.0.xxx
range in step 3, your PC’s network settings will have to be changed
to communicate with the card. Exit the VXI11_config program and
restore the PC’s network settings.