56
Cluster RAIDYNE®
(installed on the GDTx
6
xxRx).
In addition to disk chaining, RAID 0 and RAID 1,
RAIDYNE®
allows you to install
and control Array Drives of the types RAID 4 (data striping with dedicated parity
drive), RAID 5 (data striping with
distributed parity) and RAID10 (a combination
between RAID 0 and 1). Cluster RAIDYNE® includes also functions to support Mi-
crosoft Cluster Server, Novell Orion and Linux Clustering.
Note: ICP Controllers GDT8523RZ, GDT8543RZ and GDT8563RZ can be upgraded
with the Cluster Module to the corresponding GDT8623RZ, GDT8643RZ and
GDT8663RZ Controllers.
Unlike pure software solutions, e.g., Windows NT, the ICP Controllers a pure hardware RAID
solutions. All ICP Controllers are equipped with a hardware which is particularly well suited
for disk arrays. The ICP Controller firmware uses this hardware with extreme efficiency and
therefore allows you to configure disk arrays that do not load the host computer (whereas
all software-based RAID solutions more or less reduce the overall performance of the host
computer.).
The basic concept of the ICP Controller firmware is strictly modular, and
consequently, in its functioning it appears to the user as a unit construction
system.
Содержание RS Series
Страница 2: ...2...
Страница 13: ...13 L Appendix 191 L 1 Technical Data of the ICP Controller 191 L 2 Boot Error Messages 191 L 3 Index 192...
Страница 14: ...14...
Страница 15: ...15 Chapter A A A A General General General General Inform Inform Inform Informa a a ation tion tion tion...
Страница 16: ...16...
Страница 36: ...36...
Страница 42: ...42 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 43: ...43 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 SE LVD Terminator for 68 pin SE or LVDS cables SE LVD Terminator for SE LVD hard disks with SCA connector...
Страница 53: ...53 Chapter C C C C Quick Quick Quick Quick S e t u p S e t u p S e t u p S e t u p...
Страница 54: ...54...
Страница 69: ...69 Replacement either manually or through hot fix method...
Страница 71: ...71 Chapter D D D D Using Using Using Using M S D O S M S D O S M S D O S M S D O S...
Страница 72: ...72...
Страница 82: ...82...
Страница 83: ...83 Chapter E E E E Using Using Using Using NetWare NetWare NetWare NetWare...
Страница 84: ...84...
Страница 91: ...91 Chapter F F F F Using Using Using Using Windows Windows Windows Windows NT 2000 NT 2000 NT 2000 NT 2000...
Страница 92: ...92...
Страница 99: ...99 Chapter G G G G Using Using Using Using L I N U X L I N U X L I N U X L I N U X...
Страница 100: ...100...
Страница 105: ...105 Chapter H H H H Using Using Using Using SCO UNIX SCO UNIX SCO UNIX SCO UNIX...
Страница 106: ...106...
Страница 113: ...113 Chapter I I I I Using Using Using Using Uni Uni Uni Unix x x xWare Ware Ware Ware...
Страница 114: ...114...
Страница 118: ...118...
Страница 119: ...119 Chapter J J J J ICP RAID ICP RAID ICP RAID ICP RAID Console Console Console Console...
Страница 120: ...120...
Страница 152: ...152...
Страница 153: ...153 Chapter K K K K ICP RAID ICP RAID ICP RAID ICP RAID Navigator Navigator Navigator Navigator...
Страница 154: ...154...
Страница 189: ...189 Chapter L L L L Appendix Appendix Appendix Appendix...
Страница 190: ...190...