Function
iMAT 31IFBI-24VDC
9
Pos : 31 /Beko T ec hnis che D okumentati on/Übersc hriften/1/F unkti on @ 0\mod_1183637775808_15098.doc x @ 15104 @ 1 @ 1
8
Function
Pos : 32 /Beko T ec hnis che D okumentati on/Funkti on/BEKOMAT/BM IF Ableitfunkti on @ 1\mod_1294307639090_15098.doc x @ 20671 @ @ 1
Via the inlet line (1) the condensate flows into the
iMAT 31IFBI-24VDC and accumulates in the housing
(2).
A capacitively functioning sensor (3) continuously
registers the filling level and releases a signal to the
electronic interface (output Sen), as soon as the
container is filled.
(See also Chapter "Electrical installation)
The pilot valve (4) is triggered by an external signal
(input Drn). When this signal is available, the valve is
activated and the membrane (5) opens the outlet line
(6) to discharge the condensate.
With the reset of the signal, the outlet line is reclosed
tightly.