Troubleshooting and fault elimination
18
iMAT 31IFBI-24VDC
Pos : 56 /Beko T ec hnis che D okumentati on/Übersc hriften/1/F ehlers uc he und Fehl erbehebung @ 0\mod_1183637945027_15098.doc x @ 15107 @ 1 @ 1
12 Troubleshooting and fault elimination
Pos : 57 /Beko T ec hnis che D okumentati on/Fehlers uc he/BEKOMAT /Fehl ersuc he BM 31 IF/31U IF/32 IF /32U IF/32U V IF @ 2\mod_1295254011111_15098.doc x @ 20911 @ @ 1
Symptoms
Possible reasons
Measures
No detectable function
Supply voltage incorrect
Circuit board defective
External control defective
Check the connections and the supply
voltage
Check the circuit boards for possible
damage
Replace the circuit board
Input signal "Drn"
is"low", but no
condensate discharge
Feed and/or discharge pipe
blocked or obstructed
Wear and tear
Circuit board defective
Service unit defective
Minimum pressure not reached
Maximum pressure exceeded
Check feed and discharge pipe
Check whether or not the valve opens
audibly
Check the circuit board for possible
damage
Replace the circuit board
Check the operating pressure
No sensor signal "Sen"
(transistor switched,
Gnd potential) with
covered sensor
Feed pipe without sufficient slope
Cross-section not large enough
Condensate accumulation too high
(surge)
Circuit board defective
Install feed pipe with a slope
Check the circuit board for possible
damage
Replace the circuit board
Sensor signal "Sen"
(transistor open) at the
empty device
Sensor dirty
Wire breakage at the sensor
Circuit board defective
Replace the service unit
Check the circuit board for possible
damage
Replace the circuit board
Device blows off
continuously
Service unit defective or dirty
Replace the service unit