- 25 -
(2) Installation of Indoor, Outdoor unit
(1) Installation Parts Provided
A
B
1) Selection of the best location
1. Indoor unit.
2. Outdoor unit
3. Piping length and the elevation
•
There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the air
circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
• There should not be any animals or plants which could
be affected by hot air discharged.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
More than
5 cm(2")
More than 5 cm(2")
More than
5 cm(2")
More than eye level
More than 10 cm(4")
More than 10 cm(4")
More than 70 cm(28")
Indoor unit
Outdoor unit
Pipe Size
MODEL
(Cooling Capa.)
GAS
LIQUID
Max.
length
A
Max.
Elevation
B
9K, 12K
1/2"
1/4"
15m(50ft)
8m(26ft)
18K, 24K
5/8"
3/8"
15m(50ft)
8m(26ft)
1. Type "A" screw
3. Type "B" screw
4. Holder Remote-Controller
2. Installation Plate
Roof Top Installations
If it is necessary to install units on a roof structure, be
sure to elevate and level the units. Ensure the roof
structure and anchoring method are adequate for unit
location. Consult local codes regarding rooftop mounting.
NOTE: When condensing unit is to be installed on a
bonded guaranted roof, a release must be obtained
from the building owner to free the installer from all
liabilities.