5. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°F, the compres-
sor OFF temperature is the setting temperature minus 1°F.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the
Cooling operation.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
- 17 -
INTAKE AIR TEMP.
SETTING TEMP. +2°F
(Compressor ON)
SETTING TEMP. -1°F
(Compressor OFF)
Selecting
fan speed
Selecting
fan speed
Cooling
Operation
Soft Dry Operation
maximum
4 minutes
maximum
10 minutes
3 minutes
10 minutes
maximum
7 minutes
3 minutes
Cooling
Operation
COMPRESSOR
ON
OFF
ON
OFF
ON
OFF
ON
INDOOR FAN SPEED
Low
Low
Low
Low
Low