- 21 -
8. Forced Operation
• If you lose wireless remote controller, you can operate the unit with forced operation button.
• The standard conditions are shown below.
Heating Model
Room Temp
≥
76°F
70°F
≤
Room Temp < 76°F
Room temp < 70°F
Cooling
Soft Dry
Heating
High
Softe Dry Rule
High
72°F
74°F
76°F
Cooling
Model
Cooling
High
72°F
Operation Mode
Indoor Fan Speed
Setting Temp.
• Unit operates in low fan speed for first 15 seconds, then switched to proper operation mode according to intake
air temperature.
Open the front
panel upward
Forced Operation
Button
Press the Forced Operation Button.
• Press the Forced Operation Button once again
to stop operation.
9. Crank Case Heater Coil Control(only Heating model)
• When the power is applied to the set, the heater operates unconditionally.
• Except for the heating mode operation, the heater is always to be off.
• During the heating mode operation, the heater and compressor are operated by turns.
(Compressor ON
¡
Heater OFF, Compressor OFF
¡
Heater ON)